The determination of the optimal strip‐thickness of anti‐scatter grids for a given grid ratio and strip height. Issue 4 (13th February 2020)
- Record Type:
- Journal Article
- Title:
- The determination of the optimal strip‐thickness of anti‐scatter grids for a given grid ratio and strip height. Issue 4 (13th February 2020)
- Main Title:
- The determination of the optimal strip‐thickness of anti‐scatter grids for a given grid ratio and strip height
- Authors:
- Zhou, Abel
Yin, Yuming
Tan, Qi
L. White, Graeme
Davidson, Rob - Abstract:
- Abstract: In X‐ray imaging, anti‐scatter grids are used to reduce scatter radiation reaching image receptors, hence improving image quality. Optimization of grid performance is essential for improving image diagnostic quality and minimizing radiation doses to patients. This work investigated the performance of a series of grid designs modeled from the design of typically focused grid with grid ratio 8:1 (r8) and strip height 1.7 mm (h1.7) for high‐energy radiographic applications. Monte Carlo simulation was used to evaluate designs (r8h1.7) which had the strip thickness changed from 6 to 150 μm in 2 μm increments and the interspace distance fixed at 214 μm. The transmissions of radiation in grid materials were modeled by using a regression with radial‐basis‐function‐networks (RBFNS). K SNR was then determined from RBFNS models of radiation transmissions. The optimal strip‐thickness was obtained at the maximum signal‐to‐noise ratio (SNR) improvement factor ( K SNR ). For high‐energy applications at 100 peak‐kilo‐voltage (kVp) and 30 cm PMMA thickness, the optimal lead‐strip‐thickness was found approximately 74 μm resulting in a strip‐frequency approximately 35 per cm (N35). Using the optimal thickness for imaging condition at 100 kVp and 30 cm thickness, the K SNR would increase by approximately 5.3%. This work showed the existence of optimal strip‐thickness for a series of grids with a given grid‐ratio, strip‐height, strip‐, and interspace materials. The findings are usefulAbstract: In X‐ray imaging, anti‐scatter grids are used to reduce scatter radiation reaching image receptors, hence improving image quality. Optimization of grid performance is essential for improving image diagnostic quality and minimizing radiation doses to patients. This work investigated the performance of a series of grid designs modeled from the design of typically focused grid with grid ratio 8:1 (r8) and strip height 1.7 mm (h1.7) for high‐energy radiographic applications. Monte Carlo simulation was used to evaluate designs (r8h1.7) which had the strip thickness changed from 6 to 150 μm in 2 μm increments and the interspace distance fixed at 214 μm. The transmissions of radiation in grid materials were modeled by using a regression with radial‐basis‐function‐networks (RBFNS). K SNR was then determined from RBFNS models of radiation transmissions. The optimal strip‐thickness was obtained at the maximum signal‐to‐noise ratio (SNR) improvement factor ( K SNR ). For high‐energy applications at 100 peak‐kilo‐voltage (kVp) and 30 cm PMMA thickness, the optimal lead‐strip‐thickness was found approximately 74 μm resulting in a strip‐frequency approximately 35 per cm (N35). Using the optimal thickness for imaging condition at 100 kVp and 30 cm thickness, the K SNR would increase by approximately 5.3%. This work showed the existence of optimal strip‐thickness for a series of grids with a given grid‐ratio, strip‐height, strip‐, and interspace materials. The findings are useful and provide guidance to improve grid designs for better performance that will essentially lead to better image quality and better radiation protection for patients. … (more)
- Is Part Of:
- International journal of imaging systems and technology. Volume 30:Issue 4(2020)
- Journal:
- International journal of imaging systems and technology
- Issue:
- Volume 30:Issue 4(2020)
- Issue Display:
- Volume 30, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2020-0030-0004-0000
- Page Start:
- 916
- Page End:
- 925
- Publication Date:
- 2020-02-13
- Subjects:
- anti‐scatter grids -- Monte Carlo simulation -- optimal strip‐thickness -- signal‐to‐noise ratio improvement factor
Imaging systems -- Periodicals
Image processing -- Periodicals
621.367 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-1098 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ima.22409 ↗
- Languages:
- English
- ISSNs:
- 0899-9457
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.299000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14691.xml