Femoral revision in periprosthetic fractures using a titanium modular fluted tapered stem: mortality and clinical and radiological outcomes. Issue 2 (December 2020)
- Record Type:
- Journal Article
- Title:
- Femoral revision in periprosthetic fractures using a titanium modular fluted tapered stem: mortality and clinical and radiological outcomes. Issue 2 (December 2020)
- Main Title:
- Femoral revision in periprosthetic fractures using a titanium modular fluted tapered stem: mortality and clinical and radiological outcomes
- Authors:
- Munegato, Daniele
Caminita, Agostino Dario
Sotiri, Romeo
Rossi, Andrea
Bigoni, Marco
Zatti, Giovanni - Other Names:
- Zagra Luigi guest-editor.
Castelli Claudio guest-editor. - Abstract:
- Introduction: The aim of the study was to evaluate the mortality and the outcomes of femoral revision in periprosthetic femoral fractures (PFF) using a titanium modular fluted tapered stem. Methods: We retrospectively reviewed femoral revisions performed for PFF with a titanium modular fluted tapered stem in 25 patients. The average age was 74.32 years. In 21 patients the type of fracture was Vancouver B2 and type B3 in 4 cases. The mean follow-up was 29.16 (0.83–104.1) months SD ± 29.49. Results: The 30-day and 1-year mortality were 8% and 12% respectively. The mean value of the Charlson Comorbidity Index was 4.8 and the mean value of ASA score was 2.4. The average time to surgery from admittance was 5.45 days with 20% of patients operated on within 48 hours. A significant correlation was found between ASA score and mortality. The mean HHS was 76 points; good-excellent results were recorded in 56% of patients. 72% had no pain and 28% had slight pain (VAS 1–3). 52% of patients were able to walk without pain, limp or aids. The mean implant subsidence was 1.57 mm and superior to 5 mm in 2 cases. As complications we recorded 4 implant dislocations (16%) and 2 infections. Reoperation rate was 12%. Conclusions: Femoral revision with a modular fluted tapered stem in patients with periprosthetic fractures results in good clinical and radiological outcomes. However, mortality remains high and, despite the modularity design, dislocation is the most frequent complication.
- Is Part Of:
- Hip international. Volume 30:Issue 2(2020)Supplement
- Journal:
- Hip international
- Issue:
- Volume 30:Issue 2(2020)Supplement
- Issue Display:
- Volume 30, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 2
- Issue Sort Value:
- 2020-0030-0002-0000
- Page Start:
- 101
- Page End:
- 107
- Publication Date:
- 2020-12
- Subjects:
- Femoral revision -- fluted tapered stem -- hip arthroplasty -- modular stem -- periprosthetic fracture
Hip joint -- Pathophysiology -- Periodicals
Hip joint -- Diseases -- Periodicals
Hip joint -- Surgery -- Periodicals
617.581005 - Journal URLs:
- http://www.uk.sagepub.com/home.nav ↗
http://journals.sagepub.com/home/hpi ↗ - DOI:
- 10.1177/1120700020971313 ↗
- Languages:
- English
- ISSNs:
- 1120-7000
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14683.xml