- Abstract : Objective: To compare the diagnostic accuracy of ice pack test (IPT) and single-fiber EMG (SF-EMG) in patients with suspected ocular myasthenia (OM) presenting with ptosis. Methods: We studied consecutive patients referred for the clinical suspicion of OM. Patients underwent IPT and stimulated SF-EMG on the orbicularis oculi muscle. Receiver operating characteristic curve analysis was performed to determine the accuracy of IPT, SF-EMG, and their combination. Results: We included 155 patients, 102 with OM and 53 with other diagnosis (OD). The IPT had a sensitivity of 86% (95% confidence interval [CI] 79–93) and a specificity of 79% (95% CI 68–90). SF-EMG showed a sensitivity of 94% (95% CI 89–98) and a specificity of 79% (95% CI 68–90). Overall, IPT and SF-EMG showed discordant results in 30 cases, 16 OM and 14 OD. The combination of IPT and SF-EMG, using the positivity of at least one test for OM diagnosis, increased the sensitivity to 98% (95% CI 95–100), reducing the specificity to 66% (95% CI 53–78), whereas using the positivity of both tests, we obtained a sensitivity of 82% (95% CI 75–90) and a specificity of 92% (95% CI 85–99). The negativity of both tests had a 94% (95% CI 87–100) negative predictive value. Comparison of the areas under the curve showed no differences in the diagnostic accuracy of IPT, SF-EMG, and their combinations. Conclusions: IPT and SF-EMG have similar diagnostic accuracy in patients with OM presenting with ptosis. The negativity ofAbstract : Objective: To compare the diagnostic accuracy of ice pack test (IPT) and single-fiber EMG (SF-EMG) in patients with suspected ocular myasthenia (OM) presenting with ptosis. Methods: We studied consecutive patients referred for the clinical suspicion of OM. Patients underwent IPT and stimulated SF-EMG on the orbicularis oculi muscle. Receiver operating characteristic curve analysis was performed to determine the accuracy of IPT, SF-EMG, and their combination. Results: We included 155 patients, 102 with OM and 53 with other diagnosis (OD). The IPT had a sensitivity of 86% (95% confidence interval [CI] 79–93) and a specificity of 79% (95% CI 68–90). SF-EMG showed a sensitivity of 94% (95% CI 89–98) and a specificity of 79% (95% CI 68–90). Overall, IPT and SF-EMG showed discordant results in 30 cases, 16 OM and 14 OD. The combination of IPT and SF-EMG, using the positivity of at least one test for OM diagnosis, increased the sensitivity to 98% (95% CI 95–100), reducing the specificity to 66% (95% CI 53–78), whereas using the positivity of both tests, we obtained a sensitivity of 82% (95% CI 75–90) and a specificity of 92% (95% CI 85–99). The negativity of both tests had a 94% (95% CI 87–100) negative predictive value. Comparison of the areas under the curve showed no differences in the diagnostic accuracy of IPT, SF-EMG, and their combinations. Conclusions: IPT and SF-EMG have similar diagnostic accuracy in patients with OM presenting with ptosis. The negativity of both tests strongly suggests another diagnosis. Classification of evidence: This study provides Class I evidence that both the IPT and SF-EMG accurately identify patients with OM. … (more)
- Is Part Of:
- Neurology. Volume 95:Number 13(2020)
- Journal:
- Neurology
- Issue:
- Volume 95:Number 13(2020)
- Issue Display:
- Volume 95, Issue 13 (2020)
- Year:
- 2020
- Volume:
- 95
- Issue:
- 13
- Issue Sort Value:
- 2020-0095-0013-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09-29
- Subjects:
- Neurology -- Periodicals
Neurology -- Periodicals
Neurologie -- Périodiques
616.8 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_issn=0028-3878 ↗
http://www.mdconsult.com/about/journallist/192093418-5/about0nz0.html ↗
http://www.neurology.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1212/WNL.0000000000010619 ↗
- Languages:
- English
- ISSNs:
- 0028-3878
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14657.xml