Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties. (January 2020)
- Record Type:
- Journal Article
- Title:
- Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties. (January 2020)
- Main Title:
- Same sized three-way indwelling urinary catheters from various manufacturers present different irrigation and drainage properties
- Authors:
- Carneiro, Arie
Wroclawski, Marcelo Langer
Peixoto, Guilherme Andrade
Cha, Jonathan Doyun
Moran, Natasha Kouvaleski Saviano
Chen, Felipe Ko
Satkunas, Henrique Nelson
Campos, José Roberto Augusto
Garcia, Alides Maria Mendes Rasabone
Monga, Manoj
Lemos, Gustavo Caserta - Abstract:
- Background: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an in vitro setting that resembles clinical use. Methods: Three different three-way catheters were evaluated: Gold Silicone-Coated Rusch ® (Model A), 100% Silicone Rusch ® (Model B) and X-Flow Coloplast ® (Model C). Irrigation channel, drainage channel, and overall cross-sectional areas were all digitally measured. Irrigation and drainage channel flow rates were measured and correlated with their corresponding catheter cross-sectional area values. Results: Different catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow. Conclusion: Precise measurements of theBackground: The three-way indwelling urinary catheter (IUC) is used for continuous bladder irrigation and is considered the cornerstone for clinical treatment of patients with macroscopic hematuria. Although there seems to be a logical relationship between catheter size and efficacy of irrigation and drainage, we often observe relevant variations in these parameters between different brands of catheters available on the market. The aim of this study was to compare the mechanical properties of different models of latex and silicone three-way catheters in an in vitro setting that resembles clinical use. Methods: Three different three-way catheters were evaluated: Gold Silicone-Coated Rusch ® (Model A), 100% Silicone Rusch ® (Model B) and X-Flow Coloplast ® (Model C). Irrigation channel, drainage channel, and overall cross-sectional areas were all digitally measured. Irrigation and drainage channel flow rates were measured and correlated with their corresponding catheter cross-sectional area values. Results: Different catheter models of the same caliber have different internal irrigation port diameters, internal drainage port diameters and internal cuff port diameters. The Model C IUC internal irrigation port diameter is significantly larger than models A and B. When flows were evaluated, we found that in the same model, the increase in caliber of the IUC was related to an increased drainage flow, but not to an increased irrigation flow. Conclusion: Precise measurements of the internal architecture of the three-way catheter, rather than relying on the caliber itself, could assist surgeons in choosing the best product for each specific patient, while minimizing complications. … (more)
- Is Part Of:
- Therapeutic advances in urology. Volume 12(2020)
- Journal:
- Therapeutic advances in urology
- Issue:
- Volume 12(2020)
- Issue Display:
- Volume 12, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 2020
- Issue Sort Value:
- 2020-0012-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- hematuria -- indwelling catheters -- prostatectomy -- therapeutic irrigation -- urinary bladder neoplasms
Urology -- Periodicals
Urologic Diseases -- therapy -- Periodicals
Genital Diseases, Male -- therapy -- Periodicals
Urologie -- Périodiques
616.6005 - Journal URLs:
- http://intl-tau.sagepub.com/ ↗
http://tau.sagepub.com/ ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1756287219889496 ↗
- Languages:
- English
- ISSNs:
- 1756-2872
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14638.xml