A Dual‐Excitation Decoding Strategy Based on NIR Hybrid Nanocomposites for High‐Accuracy Thermal Sensing. Issue 20 (25th August 2020)
- Record Type:
- Journal Article
- Title:
- A Dual‐Excitation Decoding Strategy Based on NIR Hybrid Nanocomposites for High‐Accuracy Thermal Sensing. Issue 20 (25th August 2020)
- Main Title:
- A Dual‐Excitation Decoding Strategy Based on NIR Hybrid Nanocomposites for High‐Accuracy Thermal Sensing
- Authors:
- Yu, Shaohua
Xu, Jin
Shang, Xiaoying
Zheng, Wei
Huang, Ping
Li, Renfu
Tu, Datao
Chen, Xueyuan - Abstract:
- Abstract: Optical thermal sensing holds great promise for disease theranostics. However, traditional ratiometric thermometry methods, in which intensity ratio of two nonoverlapping emissions is defined as the thermosensitive parameter, may have a limited accuracy in temperature read‐out due to the deleterious interference from wavelength‐ and temperature‐dependent photon attenuation in tissue. To overcome this limitation, a dual‐excitation decoding strategy based on NIR hybrid nanocomposites comprising self‐assembled quantum dots (QDs) and Nd 3+ doped fluoride nanocrystals (NCs) is proposed for thermal sensing. Upon excitation at 808 nm, the intensity ratio of two emissions at identical wavelength (1057 nm) from QDs and NCs, respectively, is defined as the thermometric parameter R . By employing another 830 nm laser beam following the same optical path as 808 nm laser to exclusively excite QDs, the two overlapping emissions can be easily decoded. The acquired R proves to be inert to the detection depth in tissue, with a minimized temperature reading error of ≈2.3 °C at 35 °C (at a depth of ≈1.1 mm), while the traditional thermometry mode based on the nonoverlapping 1025 and 863 nm emissions may exhibit a large error of ≈43.0 °C. The insights provided by this work pave the way toward high‐accuracy deep‐tissue biosensing. Abstract : A dual‐excitation decoding strategy, which uses the intensity ratio of two overlapping NIR emissions from self‐assembled QDs and Nd 3+ dopedAbstract: Optical thermal sensing holds great promise for disease theranostics. However, traditional ratiometric thermometry methods, in which intensity ratio of two nonoverlapping emissions is defined as the thermosensitive parameter, may have a limited accuracy in temperature read‐out due to the deleterious interference from wavelength‐ and temperature‐dependent photon attenuation in tissue. To overcome this limitation, a dual‐excitation decoding strategy based on NIR hybrid nanocomposites comprising self‐assembled quantum dots (QDs) and Nd 3+ doped fluoride nanocrystals (NCs) is proposed for thermal sensing. Upon excitation at 808 nm, the intensity ratio of two emissions at identical wavelength (1057 nm) from QDs and NCs, respectively, is defined as the thermometric parameter R . By employing another 830 nm laser beam following the same optical path as 808 nm laser to exclusively excite QDs, the two overlapping emissions can be easily decoded. The acquired R proves to be inert to the detection depth in tissue, with a minimized temperature reading error of ≈2.3 °C at 35 °C (at a depth of ≈1.1 mm), while the traditional thermometry mode based on the nonoverlapping 1025 and 863 nm emissions may exhibit a large error of ≈43.0 °C. The insights provided by this work pave the way toward high‐accuracy deep‐tissue biosensing. Abstract : A dual‐excitation decoding strategy, which uses the intensity ratio of two overlapping NIR emissions from self‐assembled QDs and Nd 3+ doped fluoride NCs in the hybrid nanocomposites, respectively, as the ratiometric thermometric parameter, is proposed for high‐accuracy thermal sensing in vivo. … (more)
- Is Part Of:
- Advanced science. Volume 7:Issue 20(2020)
- Journal:
- Advanced science
- Issue:
- Volume 7:Issue 20(2020)
- Issue Display:
- Volume 7, Issue 20 (2020)
- Year:
- 2020
- Volume:
- 7
- Issue:
- 20
- Issue Sort Value:
- 2020-0007-0020-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-08-25
- Subjects:
- dual‐excitation decoding -- NIR hybrid nanocomposites -- photon attenuation -- thermal sensing
Science -- Periodicals
505 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2198-3844 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/advs.202001589 ↗
- Languages:
- English
- ISSNs:
- 2198-3844
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14625.xml