Analysis of a Unique Postmarket Surveillance Dataset That a Glucose Test-Strip Demonstrates no Evidence of Interference and Robust Clinical Accuracy Irrespective of the Prescription Medication Status of a Large Cohort of Patients With Diabetes. (January 2021)
- Record Type:
- Journal Article
- Title:
- Analysis of a Unique Postmarket Surveillance Dataset That a Glucose Test-Strip Demonstrates no Evidence of Interference and Robust Clinical Accuracy Irrespective of the Prescription Medication Status of a Large Cohort of Patients With Diabetes. (January 2021)
- Main Title:
- Analysis of a Unique Postmarket Surveillance Dataset That a Glucose Test-Strip Demonstrates no Evidence of Interference and Robust Clinical Accuracy Irrespective of the Prescription Medication Status of a Large Cohort of Patients With Diabetes
- Authors:
- Grady, Mike
Cameron, Hilary
Phillips, Stuart
Smith, Gillian
Setford, Steven - Abstract:
- Background: Despite a marked increase in polypharmacy in patients with diabetes there have been no thorough evaluations of the impact of polypharmacy on the accuracy of any current blood glucose monitoring (BGM) system. This study evaluated the accuracy of a BGM test-strip with respect to polypharmacy using a large clinical registry dataset. Methods: Medication profiles were analyzed for 830 subjects (334 with type 1 [T1D] and 496 with type 2 diabetes [T2D]) attending three hospitals. Blood samples were analyzed to determine clinical accuracy of the BGM test-strip compared to a laboratory comparator. Results: Across the 830 subjects, 473 different medications (41 diabetes and 432 nondiabetes) were recorded. Patients took on average 6.5 ( n = 1-23) individual medications and 4 ( n = 1-11) unique classes of medication. Clinical accuracy to EN ISO 15197:2015 criteria was met irrespective of increasing average number of individual medication, categorized from 1 to 4, 5 to 8, 9 to 12, and >12 taken per subject (97.7%, 98.4%, 98.1%, and 98.5%, respectively). Clinical accuracy to EN ISO 15197:2015 criteria was also met across 15 classes of medication using the combined dataset (98.1%; 13 003/13 253). Surveillance error grid analysis showed 98.8% (13 079/13 232) of readings presented no clinical risk. No individual class or combination of medication classes impacted clinical accuracy of the BGM test-strip. Conclusions: This comprehensive analysis for this specific test-stripBackground: Despite a marked increase in polypharmacy in patients with diabetes there have been no thorough evaluations of the impact of polypharmacy on the accuracy of any current blood glucose monitoring (BGM) system. This study evaluated the accuracy of a BGM test-strip with respect to polypharmacy using a large clinical registry dataset. Methods: Medication profiles were analyzed for 830 subjects (334 with type 1 [T1D] and 496 with type 2 diabetes [T2D]) attending three hospitals. Blood samples were analyzed to determine clinical accuracy of the BGM test-strip compared to a laboratory comparator. Results: Across the 830 subjects, 473 different medications (41 diabetes and 432 nondiabetes) were recorded. Patients took on average 6.5 ( n = 1-23) individual medications and 4 ( n = 1-11) unique classes of medication. Clinical accuracy to EN ISO 15197:2015 criteria was met irrespective of increasing average number of individual medication, categorized from 1 to 4, 5 to 8, 9 to 12, and >12 taken per subject (97.7%, 98.4%, 98.1%, and 98.5%, respectively). Clinical accuracy to EN ISO 15197:2015 criteria was also met across 15 classes of medication using the combined dataset (98.1%; 13 003/13 253). Surveillance error grid analysis showed 98.8% (13 079/13 232) of readings presented no clinical risk. No individual class or combination of medication classes impacted clinical accuracy of the BGM test-strip. Conclusions: This comprehensive analysis for this specific test-strip platform demonstrated no evidence of interference and robust clinical accuracy of this test strip, irrespective of the prescription medication status of patients with diabetes. … (more)
- Is Part Of:
- Journal of diabetes science and technology. Volume 15:Number 1(2021)
- Journal:
- Journal of diabetes science and technology
- Issue:
- Volume 15:Number 1(2021)
- Issue Display:
- Volume 15, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2021-0015-0001-0000
- Page Start:
- 82
- Page End:
- 90
- Publication Date:
- 2021-01
- Subjects:
- medications -- accuracy -- blood glucose monitor -- self-monitoring of blood glucose
Diabetes -- Periodicals
Medical technology -- Periodicals
Diabetes Mellitus -- Periodicals
616.462005 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=712321 ↗
http://www.jodsat.org/about.html ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1932296819873053 ↗
- Languages:
- English
- ISSNs:
- 1932-2968
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14604.xml