The tribology of cartilage: Mechanisms, experimental techniques, and relevance to translational tissue engineering. (October 2020)
- Record Type:
- Journal Article
- Title:
- The tribology of cartilage: Mechanisms, experimental techniques, and relevance to translational tissue engineering. (October 2020)
- Main Title:
- The tribology of cartilage: Mechanisms, experimental techniques, and relevance to translational tissue engineering
- Authors:
- Link, Jarrett M.
Salinas, Evelia Y.
Hu, Jerry C.
Athanasiou, Kyriacos A. - Abstract:
- Abstract: Diarthrodial joints, found at the ends of long bones, function to dissipate load and allow for effortless articulation. Essential to these functions are cartilages, soft hydrated tissues such as hyaline articular cartilage and the knee meniscus, as well as lubricating synovial fluid. Maintaining adequate lubrication protects cartilages from wear, but a decrease in this function leads to tissue degeneration and pathologies such as osteoarthritis. To study cartilage physiology, articular cartilage researchers have employed tribology, the study of lubrication and wear between two opposing surfaces, to characterize both native and engineered tissues. The biochemical components of synovial fluid allow it to function as an effective lubricant that exhibits shear-thinning behavior. Although tribological properties are recognized to be essential to native tissue function and a critical characteristic for translational tissue engineering, tribology is vastly understudied when compared to other mechanical properties such as compressive moduli. Further, tribometer configurations and testing modalities vary greatly across laboratories. This review aims to define commonly examined tribological characteristics and discuss the structure-function relationships of biochemical constituents known to contribute to tribological properties in native tissue, address the variations in experimental set-ups by suggesting a move toward standard testing practices, and describe howAbstract: Diarthrodial joints, found at the ends of long bones, function to dissipate load and allow for effortless articulation. Essential to these functions are cartilages, soft hydrated tissues such as hyaline articular cartilage and the knee meniscus, as well as lubricating synovial fluid. Maintaining adequate lubrication protects cartilages from wear, but a decrease in this function leads to tissue degeneration and pathologies such as osteoarthritis. To study cartilage physiology, articular cartilage researchers have employed tribology, the study of lubrication and wear between two opposing surfaces, to characterize both native and engineered tissues. The biochemical components of synovial fluid allow it to function as an effective lubricant that exhibits shear-thinning behavior. Although tribological properties are recognized to be essential to native tissue function and a critical characteristic for translational tissue engineering, tribology is vastly understudied when compared to other mechanical properties such as compressive moduli. Further, tribometer configurations and testing modalities vary greatly across laboratories. This review aims to define commonly examined tribological characteristics and discuss the structure-function relationships of biochemical constituents known to contribute to tribological properties in native tissue, address the variations in experimental set-ups by suggesting a move toward standard testing practices, and describe how tissue-engineered cartilages may be augmented to improve their tribological properties. Highlights: Loss of lubrication may harm morphology, biochemical, and mechanical properties of cartilage. Regulatory guidelines should include standardized tribology testing of neocartilage implants. Native tissue controls in tribology studies would better show translatability of neocartilages. Comprehension of synovial joints neccesitates an increase in tribological characterization. A standardized tribology testing assay would facilitate interlaboratory comparisons. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 79(2020)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 79(2020)
- Issue Display:
- Volume 79, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 79
- Issue:
- 2020
- Issue Sort Value:
- 2020-0079-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Tribology -- Diarthrodial joint -- Articular cartilage -- Meniscus -- Synovial fluid -- Tissue engineering
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2019.10.016 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14616.xml