Accumulation and spatial distribution of CO2 in the astronaut's crew quarters on the International Space Station. (November 2020)
- Record Type:
- Journal Article
- Title:
- Accumulation and spatial distribution of CO2 in the astronaut's crew quarters on the International Space Station. (November 2020)
- Main Title:
- Accumulation and spatial distribution of CO2 in the astronaut's crew quarters on the International Space Station
- Authors:
- Georgescu, Matei Razvan
Meslem, Amina
Nastase, Ilinca - Abstract:
- Abstract: In poorly ventilated confined spaces, assessing the accumulation of CO2 in the breathing zone (BZ) is important evaluating human safety. The current study presents an experimental and numerical investigation of the CO2 generation rate and spatial distribution in the crew quarters (CQ) of the International Space Station. In microgravity, density-difference based airflow is nonexistent, and CO2 accumulates around the astronaut's head if the BZ is poorly or not at all ventilated. The aim is to study the breath's influence on CO2 spatial distribution in order to circumscribe the region that needs to be ventilated in the CQ. An experimental setup was used to measure the CO2 generation rate of several test subjects on Earth in a non-ventilated full-scale model of the CQ. The experimental CO2 results were used to validate CFD simulations of the CQ with gravity, with a human model inside featuring a full respiratory cycle. The validated CFD model was then used without gravity for a CO2 accumulation study. The respiratory cycle was analyzed in order to propose a rigorous definition of the BZ based on a frequency analysis of the breath. Results show that CO2 concentrations in the identified BZ are greater in the absence of gravity compared to a similar situation with gravity. It is believed that the ventilation system presently in place in the CQ does not effectively ventilate this strategic area, therefore a personalized ventilation type solution should be studied in theAbstract: In poorly ventilated confined spaces, assessing the accumulation of CO2 in the breathing zone (BZ) is important evaluating human safety. The current study presents an experimental and numerical investigation of the CO2 generation rate and spatial distribution in the crew quarters (CQ) of the International Space Station. In microgravity, density-difference based airflow is nonexistent, and CO2 accumulates around the astronaut's head if the BZ is poorly or not at all ventilated. The aim is to study the breath's influence on CO2 spatial distribution in order to circumscribe the region that needs to be ventilated in the CQ. An experimental setup was used to measure the CO2 generation rate of several test subjects on Earth in a non-ventilated full-scale model of the CQ. The experimental CO2 results were used to validate CFD simulations of the CQ with gravity, with a human model inside featuring a full respiratory cycle. The validated CFD model was then used without gravity for a CO2 accumulation study. The respiratory cycle was analyzed in order to propose a rigorous definition of the BZ based on a frequency analysis of the breath. Results show that CO2 concentrations in the identified BZ are greater in the absence of gravity compared to a similar situation with gravity. It is believed that the ventilation system presently in place in the CQ does not effectively ventilate this strategic area, therefore a personalized ventilation type solution should be studied in the future. Highlights: Astronauts are at risk of CO2 intoxication in the confined environment they inhabit. An experimentally validated CFD model is used for analyzing CO2 accumulation. Fourier transforms of breath flow velocity can spatially delimit the breathing zone. In microgravity air is charged with more CO2 than a similar situation on Earth. Local ventilation of the breathing zone is necessary to disperse CO2 accumulation. … (more)
- Is Part Of:
- Building and environment. Volume 185(2020)
- Journal:
- Building and environment
- Issue:
- Volume 185(2020)
- Issue Display:
- Volume 185, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 185
- Issue:
- 2020
- Issue Sort Value:
- 2020-0185-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- ISS ventilation -- CO2 accumulation in microgravity -- Human breathing simulation -- Breathing zone definition
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2020.107278 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14620.xml