Ultrasound-guided intraoperative electron beam radiation therapy: A phantom study. (October 2020)
- Record Type:
- Journal Article
- Title:
- Ultrasound-guided intraoperative electron beam radiation therapy: A phantom study. (October 2020)
- Main Title:
- Ultrasound-guided intraoperative electron beam radiation therapy: A phantom study
- Authors:
- Ma, Pan
Li, Minghui
Chen, Xinyuan
Tian, Yuan
Niu, Chuanmeng
Feng, Qinfu
Dai, Jianrong - Abstract:
- Highlights: The ultrasound-guided intra-operative radiation therapy method was established. The intra-operative 3D dose distribution could be provided. The compensator may be an alternative to deliver intra-operative radiation therapy. Abstract: Purpose: To develop the method for ultrasound (US)-guided intra-operative electron beam radiation therapy (IOERT). Methods: We first established the simulation, planning, and delivery methods for US-guided IOERT and constructed appropriate hardware (the multi-function applicator, accessories, and US phantom). We tested our US-guided IOERT method using this hardware and the Monte Carlo simulation IOERT treatment planning system (TPS). The IOERT TPS used a compensator to build the conformal dose distribution. Then, we used the TPS to evaluate the effect of setup uncertainty on target coverage by introducing phantom setup error ranging from 0 mm to 10 mm to the plans with and without the compensator. Results: The simulation, planning, and delivery methods for US-guided IOERT were introduced and validated on a phantom. A complete technique for US-guided IOERT was established. Target coverage decreased by about 12% and 29% as the phantom setup error increased to 5 mm and 10 mm for the plans with compensator, respectively. Without compensator, the corresponding target coverage decreases were 2% and 13%, respectively. Conclusion: In our study, we developed the multi-function applicator, US Phantom, and TPS for IOERT. The procedures includedHighlights: The ultrasound-guided intra-operative radiation therapy method was established. The intra-operative 3D dose distribution could be provided. The compensator may be an alternative to deliver intra-operative radiation therapy. Abstract: Purpose: To develop the method for ultrasound (US)-guided intra-operative electron beam radiation therapy (IOERT). Methods: We first established the simulation, planning, and delivery methods for US-guided IOERT and constructed appropriate hardware (the multi-function applicator, accessories, and US phantom). We tested our US-guided IOERT method using this hardware and the Monte Carlo simulation IOERT treatment planning system (TPS). The IOERT TPS used a compensator to build the conformal dose distribution. Then, we used the TPS to evaluate the effect of setup uncertainty on target coverage by introducing phantom setup error ranging from 0 mm to 10 mm to the plans with and without the compensator. Results: The simulation, planning, and delivery methods for US-guided IOERT were introduced and validated on a phantom. A complete technique for US-guided IOERT was established. Target coverage decreased by about 12% and 29% as the phantom setup error increased to 5 mm and 10 mm for the plans with compensator, respectively. Without compensator, the corresponding target coverage decreases were 2% and 13%, respectively. Conclusion: In our study, we developed the multi-function applicator, US Phantom, and TPS for IOERT. The procedures included not only dose distribution planning, but also intraoperative US imaging, which provided the information necessary during surgery to improve IOERT quality assurance. Target coverage was more sensitive to setup errors with compensator compared to no compensator. Further studies are needed to validate the clinical efficacy of this US-guided IOERT method. … (more)
- Is Part Of:
- Physica medica. Volume 78(2020)
- Journal:
- Physica medica
- Issue:
- Volume 78(2020)
- Issue Display:
- Volume 78, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 78
- Issue:
- 2020
- Issue Sort Value:
- 2020-0078-2020-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2020-10
- Subjects:
- Image-guided radiation therapy -- Intraoperative electron beam radiation therapy -- Ultrasound imaging
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.06.021 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14590.xml