Glenoid bone strain after anatomical total shoulder arthroplasty: In vitro measurements with micro-CT and digital volume correlation. (November 2020)
- Record Type:
- Journal Article
- Title:
- Glenoid bone strain after anatomical total shoulder arthroplasty: In vitro measurements with micro-CT and digital volume correlation. (November 2020)
- Main Title:
- Glenoid bone strain after anatomical total shoulder arthroplasty: In vitro measurements with micro-CT and digital volume correlation
- Authors:
- Boulanaache, Y.
Becce, F.
Farron, A.
Pioletti, D.P.
Terrier, A. - Abstract:
- Highlights: Glenoid bone displacement and strain evaluated during 1500 N applied loading. Digital Volume Correlation (DVC) applied to measure implanted glenoid bone strain. Loading device developed to fit in micro-CT scanner. In-depth error analysis of the DVC technique evaluated. DVC measurement technique suitable to provide glenoid bone full-field strain map. Abstract: Glenoid implant loosening remains a major source of failure and concern after anatomical total shoulder arthroplasty (aTSA). It is assumed to be associated with eccentric loading and excessive bone strain, but direct measurement of bone strain after aTSA is not available yet. Therefore, our objective was to develop an in vitro technique for measuring bone strain around a loaded glenoid implant. A custom loading device (1500 N) was designed to fit within a micro-CT scanner, to use digital volume correlation for measuring displacement and calculating strain. Errors were evaluated with three pairs of unloaded scans. The average displacement random error of three pairs of unloaded scans was 6.1 µm. Corresponding systematic and random errors of strain components were less than 806.0 µε and 2039.9 µε, respectively. The average strain accuracy (MAER) and precision (SDER) were 694.3 µε and 440.3 µε, respectively. The loaded minimum principal strain (8738.9 µε) was 12.6 times higher than the MAER (694.3 µε) on average, and was above the MAER for most of the glenoid bone volume (98.1%). Therefore, this techniqueHighlights: Glenoid bone displacement and strain evaluated during 1500 N applied loading. Digital Volume Correlation (DVC) applied to measure implanted glenoid bone strain. Loading device developed to fit in micro-CT scanner. In-depth error analysis of the DVC technique evaluated. DVC measurement technique suitable to provide glenoid bone full-field strain map. Abstract: Glenoid implant loosening remains a major source of failure and concern after anatomical total shoulder arthroplasty (aTSA). It is assumed to be associated with eccentric loading and excessive bone strain, but direct measurement of bone strain after aTSA is not available yet. Therefore, our objective was to develop an in vitro technique for measuring bone strain around a loaded glenoid implant. A custom loading device (1500 N) was designed to fit within a micro-CT scanner, to use digital volume correlation for measuring displacement and calculating strain. Errors were evaluated with three pairs of unloaded scans. The average displacement random error of three pairs of unloaded scans was 6.1 µm. Corresponding systematic and random errors of strain components were less than 806.0 µε and 2039.9 µε, respectively. The average strain accuracy (MAER) and precision (SDER) were 694.3 µε and 440.3 µε, respectively. The loaded minimum principal strain (8738.9 µε) was 12.6 times higher than the MAER (694.3 µε) on average, and was above the MAER for most of the glenoid bone volume (98.1%). Therefore, this technique proves to be accurate and precise enough to eventually compare glenoid implant designs, fixation techniques, or to validate numerical models of specimens under similar loading. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- Medical engineering & physics. Volume 85(2020)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 85(2020)
- Issue Display:
- Volume 85, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 85
- Issue:
- 2020
- Issue Sort Value:
- 2020-0085-2020-0000
- Page Start:
- 48
- Page End:
- 54
- Publication Date:
- 2020-11
- Subjects:
- Bone strain -- Digital volume correlation -- Glenoid -- Micro-CT -- Total shoulder arthroplasty
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2020.09.009 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14590.xml