Pre-heating time and exposure duration: Effects on post-irradiation properties of a thermo-viscous resin-composite. Issue 6 (June 2020)
- Record Type:
- Journal Article
- Title:
- Pre-heating time and exposure duration: Effects on post-irradiation properties of a thermo-viscous resin-composite. Issue 6 (June 2020)
- Main Title:
- Pre-heating time and exposure duration: Effects on post-irradiation properties of a thermo-viscous resin-composite
- Authors:
- Yang, Jiawei
Silikas, Nikolaos
Watts, David C. - Abstract:
- Abstract: Objective: To evaluate the effects of pre-heating time and exposure duration on the degree of conversion (DC), maximum rate of polymerization (RPmax ), polymerization shrinkage strain (PS) and surface micro-hardness (VHN) of Viscalor . Methods: Viscalor syringes were pre-heated using a Caps Warmer (VOCO, Germany) in T3 mode (at 68 °C) for 30 s (T3-30s) and 3 min (T3-3min) and then the composite paste was extruded into appropriately sized molds. Light irradiation was applied at zero distance from the upper surface with a LED-LCU of mean irradiance 1200 mW/cm 2 for either 20 or 40 s. The real-time polymerization kinetics and DC at 5 min and 24 h post-irradiation (DC5min and DC24h ) were measured using ATR-FTIR ( n = 3). PS was obtained with the bonded-disk technique ( n = 3). Top and bottom Vickers micro-hardness (VHNtop and VHNbottom ) were measured at 5 min post-irradiation and after 24 h dry storage ( n = 5). Data were analysed using one-way ANOVA, two-way ANOVA, independent t -test and Tukey post hoc tests ( p < 0.05). Results: Polymerization kinetic curves of Viscalor from 0 to 15 min were similar for different pre-heating times and exposure durations. Pre-heated Viscalor (T3-30s and T3-3min) with 40 s exposure had greater VHNtop and VHNbottom than for Viscalor (no heat) ( p < 0.05). Exposure duration did not significantly affect DC, RPmax and PS ( p > 0.05). After 24 h storage, DC and VHN increased. Pre-heating did not increase the DC24h, relative to noAbstract: Objective: To evaluate the effects of pre-heating time and exposure duration on the degree of conversion (DC), maximum rate of polymerization (RPmax ), polymerization shrinkage strain (PS) and surface micro-hardness (VHN) of Viscalor . Methods: Viscalor syringes were pre-heated using a Caps Warmer (VOCO, Germany) in T3 mode (at 68 °C) for 30 s (T3-30s) and 3 min (T3-3min) and then the composite paste was extruded into appropriately sized molds. Light irradiation was applied at zero distance from the upper surface with a LED-LCU of mean irradiance 1200 mW/cm 2 for either 20 or 40 s. The real-time polymerization kinetics and DC at 5 min and 24 h post-irradiation (DC5min and DC24h ) were measured using ATR-FTIR ( n = 3). PS was obtained with the bonded-disk technique ( n = 3). Top and bottom Vickers micro-hardness (VHNtop and VHNbottom ) were measured at 5 min post-irradiation and after 24 h dry storage ( n = 5). Data were analysed using one-way ANOVA, two-way ANOVA, independent t -test and Tukey post hoc tests ( p < 0.05). Results: Polymerization kinetic curves of Viscalor from 0 to 15 min were similar for different pre-heating times and exposure durations. Pre-heated Viscalor (T3-30s and T3-3min) with 40 s exposure had greater VHNtop and VHNbottom than for Viscalor (no heat) ( p < 0.05). Exposure duration did not significantly affect DC, RPmax and PS ( p > 0.05). After 24 h storage, DC and VHN increased. Pre-heating did not increase the DC24h, relative to no pre-heating ( p > 0.05). Two-way ANOVA showed that there was no significant interaction between pre-heating time and exposure duration ( p > 0.05). Significance: Increasing irradiation time from 20 to 40 s did not affect DC, RPmax or PS, but increased VHNtop . Composite pre-heating had no adverse effect through any premature polymerization. For Viscalor, 3 min pre-heating and 20 s irradiation were sufficient to provide adequate hardness, without increasing PS or compromising polymerization kinetics. … (more)
- Is Part Of:
- Dental materials. Volume 36:Issue 6(2020)
- Journal:
- Dental materials
- Issue:
- Volume 36:Issue 6(2020)
- Issue Display:
- Volume 36, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 36
- Issue:
- 6
- Issue Sort Value:
- 2020-0036-0006-0000
- Page Start:
- 787
- Page End:
- 793
- Publication Date:
- 2020-06
- Subjects:
- Pre-heating -- Exposure duration -- Degree of conversion -- Micro-hardness -- Polymerization shrinkage strain
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2020.03.025 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14591.xml