A head‐to‐head comparison of three coronary fractional flow reserve measurement technologies: The fractional flow reserve‐device study. Issue 6 (12th August 2019)
- Record Type:
- Journal Article
- Title:
- A head‐to‐head comparison of three coronary fractional flow reserve measurement technologies: The fractional flow reserve‐device study. Issue 6 (12th August 2019)
- Main Title:
- A head‐to‐head comparison of three coronary fractional flow reserve measurement technologies: The fractional flow reserve‐device study
- Authors:
- Beygui, Farzin
Lemaître, Adrien
Bignon, Mathieu
Wain‐Hobson, Julien
Briet, Clément
Ardouin, Pierre
Sabatier, Remi
Parienti, Jean‐Jacques
Blanchart, Katrien
Roule, Vincent - Abstract:
- Abstract: Objectives: To compare three FFR technologies: the electric‐sensor Pressurewire® (P), the optic‐sensor Comet® (C) guidewire, and the optic‐sensor Navvus® (N) microcatheter. Background: Different technologies are used to measure fractional flow reserve (FFR) for the functional assessment of coronary lesions with potential discrepancies. Methods: Sixty‐six FFR measurements performed on 32 lesions using each technology were used for a paired comparison of FFR on simultaneous measurements and in clinically relevant conditions (guidewires alone, N on a guidewire). Results: Simultaneous measurements of FFR were significantly ( p < .0001) correlated between systems ( ρ = 0.88, 0.81 and 0.86 for P and N, P and C and, C and N, respectively). The presence of the N microcatheter, led to reduced values of FFR measured by P or C guidewires ( p < .0001). The concomitant presence of P and C guidewires led to significantly lower FFR values ( p < .0001) measured by P but not by C. In clinically relevant conditions, values of FFR measured by the optic‐sensor C guidewire and N catheter were similar and lower than those measured by the P guidewire ( p < .0001). The agreement between the three technologies (FFR ≤ 0.80) was 94%. Conclusions: FFR values simultaneously measured by three different technologies, are strongly correlated, and provide strongly concordant results. However, significant differences are found between values of FFR. The presence of N, but also C lead to aAbstract: Objectives: To compare three FFR technologies: the electric‐sensor Pressurewire® (P), the optic‐sensor Comet® (C) guidewire, and the optic‐sensor Navvus® (N) microcatheter. Background: Different technologies are used to measure fractional flow reserve (FFR) for the functional assessment of coronary lesions with potential discrepancies. Methods: Sixty‐six FFR measurements performed on 32 lesions using each technology were used for a paired comparison of FFR on simultaneous measurements and in clinically relevant conditions (guidewires alone, N on a guidewire). Results: Simultaneous measurements of FFR were significantly ( p < .0001) correlated between systems ( ρ = 0.88, 0.81 and 0.86 for P and N, P and C and, C and N, respectively). The presence of the N microcatheter, led to reduced values of FFR measured by P or C guidewires ( p < .0001). The concomitant presence of P and C guidewires led to significantly lower FFR values ( p < .0001) measured by P but not by C. In clinically relevant conditions, values of FFR measured by the optic‐sensor C guidewire and N catheter were similar and lower than those measured by the P guidewire ( p < .0001). The agreement between the three technologies (FFR ≤ 0.80) was 94%. Conclusions: FFR values simultaneously measured by three different technologies, are strongly correlated, and provide strongly concordant results. However, significant differences are found between values of FFR. The presence of N, but also C lead to a decrease of FFR measured by P. In clinically relevant conditions, the two optic‐sensor technologies provide similar FFR measurements, lower than those measured by the piezo‐electric technology suggesting a sensor‐technology‐related measurement variability. Clinical trial registration: NCT#03052803. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 95:Issue 6(2020)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 95:Issue 6(2020)
- Issue Display:
- Volume 95, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 95
- Issue:
- 6
- Issue Sort Value:
- 2020-0095-0006-0000
- Page Start:
- 1094
- Page End:
- 1101
- Publication Date:
- 2019-08-12
- Subjects:
- coronary artery disease -- coronary physiology -- fractional flow reserve
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28433 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14590.xml