Clinical use of a 180‐day implantable glucose sensor improves glycated haemoglobin and time in range in patients with type 1 diabetes. Issue 7 (27th February 2020)
- Record Type:
- Journal Article
- Title:
- Clinical use of a 180‐day implantable glucose sensor improves glycated haemoglobin and time in range in patients with type 1 diabetes. Issue 7 (27th February 2020)
- Main Title:
- Clinical use of a 180‐day implantable glucose sensor improves glycated haemoglobin and time in range in patients with type 1 diabetes
- Authors:
- Irace, Concetta
Cutruzzolà, Antonio
Nuzzi, Annamaria
Assaloni, Roberta
Brunato, Barbara
Pitocco, Dario
Tartaglione, Linda
Di Molfetta, Sergio
Cignarelli, Angelo
Laviola, Luigi
Citro, Giuseppe
Lovati, Elisabetta
Gnasso, Agostino
Tweden, Katherine S
Kaufman, Francine R - Abstract:
- Abstract: Aims: This real‐world study evaluated the changes in glycated haemoglobin (HbA1c) and continuous glucose monitoring (CGM) metrics associated with use of the implantable 180‐day Eversense CGM System (Eversense) in patients with type 1 diabetes. Materials and methods: This was a prospective, multicentre, observational study among adult participants aged ≥18 years with type 1 diabetes across seven diabetes‐care centres in Italy who had Eversense inserted for the first time. HbA1c was measured at baseline and at 180 days. Changes in time in range [TIR (glucose 70–180 mg/dL)], time above range [TAR (glucose >180 mg/dL)], time below range [TBR (glucose <70 mg/dL)] and glycaemic variability were also assessed. Data were also analysed by previous CGM use and by mode of insulin delivery. Results: One‐hundred patients were enrolled (mean age 36 ± 12 years, mean baseline HbA1c 7.4 ± 0.92% [57 ± 10 mmol/mol]). Fifty‐six per cent of patients were users of the continuous subcutaneous insulin infusion pump and 45% were previous users of CGM. HbA1c significantly decreased in patients after 180 days of sensor wear (−0.43% ± 0.69%, 5 ± 8 mmol/mol, P < 0.0001). As expected, CGM‐naïve patients achieved the greatest reduction in HbA1c (−0.74% ± 0.48%, 8 ± 5 mmol/mol). TIR significantly increased and TAR and mean daily sensor glucose significantly decreased while TBR did not change after 180 days of sensor wear. Conclusions: Real‐world clinical use of the Eversense CGM System forAbstract: Aims: This real‐world study evaluated the changes in glycated haemoglobin (HbA1c) and continuous glucose monitoring (CGM) metrics associated with use of the implantable 180‐day Eversense CGM System (Eversense) in patients with type 1 diabetes. Materials and methods: This was a prospective, multicentre, observational study among adult participants aged ≥18 years with type 1 diabetes across seven diabetes‐care centres in Italy who had Eversense inserted for the first time. HbA1c was measured at baseline and at 180 days. Changes in time in range [TIR (glucose 70–180 mg/dL)], time above range [TAR (glucose >180 mg/dL)], time below range [TBR (glucose <70 mg/dL)] and glycaemic variability were also assessed. Data were also analysed by previous CGM use and by mode of insulin delivery. Results: One‐hundred patients were enrolled (mean age 36 ± 12 years, mean baseline HbA1c 7.4 ± 0.92% [57 ± 10 mmol/mol]). Fifty‐six per cent of patients were users of the continuous subcutaneous insulin infusion pump and 45% were previous users of CGM. HbA1c significantly decreased in patients after 180 days of sensor wear (−0.43% ± 0.69%, 5 ± 8 mmol/mol, P < 0.0001). As expected, CGM‐naïve patients achieved the greatest reduction in HbA1c (−0.74% ± 0.48%, 8 ± 5 mmol/mol). TIR significantly increased and TAR and mean daily sensor glucose significantly decreased while TBR did not change after 180 days of sensor wear. Conclusions: Real‐world clinical use of the Eversense CGM System for 180 days was associated with significant improvements in HbA1c and CGM metrics among adults with type 1 diabetes. The study is registered on clinicaltrials.gov (NCT04160156). … (more)
- Is Part Of:
- Diabetes, obesity & metabolism. Volume 22:Issue 7(2020)
- Journal:
- Diabetes, obesity & metabolism
- Issue:
- Volume 22:Issue 7(2020)
- Issue Display:
- Volume 22, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 7
- Issue Sort Value:
- 2020-0022-0007-0000
- Page Start:
- 1056
- Page End:
- 1061
- Publication Date:
- 2020-02-27
- Subjects:
- Diabetes -- Periodicals
Obesity -- Periodicals
Metabolism -- Disorders -- Periodicals
Clinical pharmacology -- Periodicals
616.462 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1462-8902&site=1 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1463-1326 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/dom.13993 ↗
- Languages:
- English
- ISSNs:
- 1462-8902
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3579.601970
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14590.xml