Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient‐ and spin‐echo (GRASE) in breath‐hold (BH) magnetic resonance cholangiopancreatography (MRCP). Issue 3 (16th July 2019)
- Record Type:
- Journal Article
- Title:
- Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient‐ and spin‐echo (GRASE) in breath‐hold (BH) magnetic resonance cholangiopancreatography (MRCP). Issue 3 (16th July 2019)
- Main Title:
- Comparison and evaluation of the efficacy of compressed SENSE (CS) and gradient‐ and spin‐echo (GRASE) in breath‐hold (BH) magnetic resonance cholangiopancreatography (MRCP)
- Authors:
- He, Ming
Xu, Jin
Sun, Zhaoyong
Wang, Shitian
Zhu, Liang
Wang, Xiaoqi
Wang, Jiazheng
Feng, Feng
Xue, Huadan
Jin, Zhengyu - Abstract:
- Abstract : Contract grant sponsor: Chinese Academy of Medical Sciences (CAMS) Initiative for Innovative Medicine; Contract grant number: 2017‐I2M‐1‐001; Contract grant sponsor: Outstanding Youth Fund of Peking Union Medical College Hospital; Contract grant number: JQ201704; Contract grant sponsor: National Natural Science Foundation of China; Contract grant number: 81871512; Contract grant sponsor: National Public Welfare Basic Scientific Research Program of Chinese Academy of Medical Sciences; Contract grant numbers: 2018PT32003 and 2017PT32004. Background: Both compressed‐sensing (CS) and gradient‐ and spin‐echo (GRASE) sequences can achieve 3D magnetic resonance cholangiopancreatography (MRCP) with a single breath‐hold (BH). This work hypothesized that compared with conventional navigator‐triggered (NT)‐MRCP, the two BH‐MRCP protocols, GRASE and CS, may provide better imaging quality, especially for patients with irregular breathing. Purpose: To evaluate and compare the image quality and diagnostic performance of three MRCP protocols. Study Type: Prospective. Subjects: Seventy‐four patients suspected to have duct‐related pathologies were enrolled. Field Strength: 3.0T. Sequences: NT‐MRCP, BH‐CS‐MRCP, and BH‐GRASE‐MRCP. Assessment: Breath regularity was evaluated subjectively according to the respiratory waves. The acquisition time was compared. The pancreaticobiliary system was divided into 12 segments and evaluated on a 5‐point scale. The diagnostic performance of theAbstract : Contract grant sponsor: Chinese Academy of Medical Sciences (CAMS) Initiative for Innovative Medicine; Contract grant number: 2017‐I2M‐1‐001; Contract grant sponsor: Outstanding Youth Fund of Peking Union Medical College Hospital; Contract grant number: JQ201704; Contract grant sponsor: National Natural Science Foundation of China; Contract grant number: 81871512; Contract grant sponsor: National Public Welfare Basic Scientific Research Program of Chinese Academy of Medical Sciences; Contract grant numbers: 2018PT32003 and 2017PT32004. Background: Both compressed‐sensing (CS) and gradient‐ and spin‐echo (GRASE) sequences can achieve 3D magnetic resonance cholangiopancreatography (MRCP) with a single breath‐hold (BH). This work hypothesized that compared with conventional navigator‐triggered (NT)‐MRCP, the two BH‐MRCP protocols, GRASE and CS, may provide better imaging quality, especially for patients with irregular breathing. Purpose: To evaluate and compare the image quality and diagnostic performance of three MRCP protocols. Study Type: Prospective. Subjects: Seventy‐four patients suspected to have duct‐related pathologies were enrolled. Field Strength: 3.0T. Sequences: NT‐MRCP, BH‐CS‐MRCP, and BH‐GRASE‐MRCP. Assessment: Breath regularity was evaluated subjectively according to the respiratory waves. The acquisition time was compared. The pancreaticobiliary system was divided into 12 segments and evaluated on a 5‐point scale. The diagnostic performance of the three MRCPs was evaluated and compared. Statistical Tests: The Friedman test with a post‐hoc test, receiver operating characteristic (ROC) curve analysis, McNemar test, and Kendall's W test were used. Results: The BH‐MRCP decreased the scan time significantly ( P < 0.05). The overall imaging scores of GRASE‐MRCP and CS‐MRCP were significantly higher than that of NT‐MRCP for patients with irregular breathing (4.283 and 4.283 vs. 3.000, both P < 0.05). Compared with NT‐MRCP, the diagnostic performance of BH‐CS and BH‐GRASE MRCP was significantly improved for patients with irregular breathing (AUC = 0.860 and 0.863 vs. 0.572, both P < 0.001). Data Conclusion: Compared with conventional NT‐MRCP, the overall imaging quality and diagnostic performance of BH‐CS and BH‐GRASE MRCP were not significantly different for patients with regular breathing and significantly superior for patients with irregular breathing. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:824–832. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 51:Issue 3(2020)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 51:Issue 3(2020)
- Issue Display:
- Volume 51, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 51
- Issue:
- 3
- Issue Sort Value:
- 2020-0051-0003-0000
- Page Start:
- 824
- Page End:
- 832
- Publication Date:
- 2019-07-16
- Subjects:
- magnetic resonance cholangiopancreatography -- breath holding -- three‐dimensional imaging -- biliary tract
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.26863 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14569.xml