Characteristics of ventricular fibrillation in relation to cardiac aetiology and shock success: A waveform analysis study in ICD-patients. (January 2015)
- Record Type:
- Journal Article
- Title:
- Characteristics of ventricular fibrillation in relation to cardiac aetiology and shock success: A waveform analysis study in ICD-patients. (January 2015)
- Main Title:
- Characteristics of ventricular fibrillation in relation to cardiac aetiology and shock success: A waveform analysis study in ICD-patients
- Authors:
- Bonnes, Judith L.
Keuper, Wessel
Westra, Sjoerd W.
Zegers, Erwin S.
Oostendorp, Thom F.
Brouwer, Marc A.
Smeets, Joep L.R.M. - Abstract:
- Abstract: Background: Ventricular fibrillation (VF) waveform characteristics are associated with cardiac arrest duration and defibrillation success. Recent animal studies found that VF characteristics and shock success also depend on the presence of myocardial infarction (MI). In patients, VF induction after implantable cardioverter defibrillator (ICD) implantation offers a unique setting to study early VF characteristics: we studied the relation with cardiac disease – either presence or absence of a previous MI – and with shock success. Methods: Retrospective cohort study of ICD-patients who underwent defibrillation testing, 117 (63%) with and 69 (37%) without a previous MI. Intracardiac recordings of induced VF were analysed using Fourier analysis. Results: In previous MI-patients, the fundamental frequency and organisation index of the VF signal were significantly lower as compared with patients without a previous MI: 4.9 Hz ± 0.6 vs. 5.2 Hz ± 0.6 ( p = 0.005) and 56% ± 10 vs. 60% ± 9 ( p = 0.001), respectively. The median frequency was not different ( p = 0.25). We found no association between VF characteristics and ICD shock success. Conclusions: In analogy with observations in animals, we found that a history of a previous MI was associated with slower and less organised VF. In our cohort of ICD-patients, early VF waveform characteristics were not associated with shock outcomes. Further study is warranted to determine to what extent VF characteristics are influencedAbstract: Background: Ventricular fibrillation (VF) waveform characteristics are associated with cardiac arrest duration and defibrillation success. Recent animal studies found that VF characteristics and shock success also depend on the presence of myocardial infarction (MI). In patients, VF induction after implantable cardioverter defibrillator (ICD) implantation offers a unique setting to study early VF characteristics: we studied the relation with cardiac disease – either presence or absence of a previous MI – and with shock success. Methods: Retrospective cohort study of ICD-patients who underwent defibrillation testing, 117 (63%) with and 69 (37%) without a previous MI. Intracardiac recordings of induced VF were analysed using Fourier analysis. Results: In previous MI-patients, the fundamental frequency and organisation index of the VF signal were significantly lower as compared with patients without a previous MI: 4.9 Hz ± 0.6 vs. 5.2 Hz ± 0.6 ( p = 0.005) and 56% ± 10 vs. 60% ± 9 ( p = 0.001), respectively. The median frequency was not different ( p = 0.25). We found no association between VF characteristics and ICD shock success. Conclusions: In analogy with observations in animals, we found that a history of a previous MI was associated with slower and less organised VF. In our cohort of ICD-patients, early VF waveform characteristics were not associated with shock outcomes. Further study is warranted to determine to what extent VF characteristics are influenced by the underlying aetiology on the one hand, and time delay on the other. These findings could improve insight into the potential value of VF analysis to guide shock delivery. … (more)
- Is Part Of:
- Resuscitation. Volume 86(2015)
- Journal:
- Resuscitation
- Issue:
- Volume 86(2015)
- Issue Display:
- Volume 86, Issue 2015 (2015)
- Year:
- 2015
- Volume:
- 86
- Issue:
- 2015
- Issue Sort Value:
- 2015-0086-2015-0000
- Page Start:
- 95
- Page End:
- 99
- Publication Date:
- 2015-01
- Subjects:
- Ventricular fibrillation -- Fourier analysis -- Ischemic heart disease -- Defibrillation -- Implantable cardioverter defibrillator
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2014.10.003 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14573.xml