Improvement of image performance in digital breast tomosynthesis (DBT) by incorporating a compressed-sensing (CS)-based deblurring scheme. (October 2016)
- Record Type:
- Journal Article
- Title:
- Improvement of image performance in digital breast tomosynthesis (DBT) by incorporating a compressed-sensing (CS)-based deblurring scheme. (October 2016)
- Main Title:
- Improvement of image performance in digital breast tomosynthesis (DBT) by incorporating a compressed-sensing (CS)-based deblurring scheme
- Authors:
- Kim, Kyuseok
Park, Yeonok
Cho, Heemoon
Cho, Hyosung
Je, Uikyu
Park, Chulkyu
Lim, Hyunwoo
Park, Soyoung
Woo, Taeho
Choi, Sungil - Abstract:
- Abstract: In this work, we investigated a compressed-sensing (CS)-based deblurring scheme incorporated with the total-variation (TV) regularization penalty for image deblurring of high accuracy and adopted it into the image reconstruction in conventional digital breast tomosynthesis (DBT). We implemented the proposed algorithm and performed a systematic simulation to demonstrate its viability for improving the image performance in DBT as well as two-dimensional (2D) mammography. In the simulation, blurred noisy projection images of a 3D numerical breast phantom were generated by convolving their original (or exact ) version by a designed 2D Gaussian filter kernel (standard deviation=2 in pixel unit, kernel size=11×11), followed by adding Gaussian noise (mean=0, variance=0.05), and deblurred by using the algorithm before performing the DBT reconstruction procedure. Here the projection images were taken with a half tomographic angle of θ=20° and an angle step of Δθ=2°. We investigated the image performance of the reconstructed DBT images quantitatively in terms of the modulation and the slice-sensitive profile (SSP). Highlights: A compressed-sensing (CS)-based deblurring scheme is performed. We implement the proposed algorithm and performed a systematic simulation. A blurred noisy projection images of a 3D numerical breast phantom is generated. The improving of the image performance is done in DBT as well as 2D mammography.
- Is Part Of:
- Radiation physics and chemistry. Volume 127(2016:Oct.)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 127(2016:Oct.)
- Issue Display:
- Volume 127 (2016)
- Year:
- 2016
- Volume:
- 127
- Issue Sort Value:
- 2016-0127-0000-0000
- Page Start:
- 147
- Page End:
- 154
- Publication Date:
- 2016-10
- Subjects:
- Deblurring -- Compressed-sensing (CS) -- Digital breast tomosynthesis (DBT) -- Filter kernel
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2016.06.025 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14563.xml