Precision and accuracy of robot‐assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty. Issue 5 (19th August 2020)
- Record Type:
- Journal Article
- Title:
- Precision and accuracy of robot‐assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty. Issue 5 (19th August 2020)
- Main Title:
- Precision and accuracy of robot‐assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty
- Authors:
- Cozzi Lepri, Andrea
Villano, Marco
Innocenti, Matteo
Porciatti, Tommaso
Matassi, Fabrizio
Civinini, Roberto - Abstract:
- Abstract: Background: Semi‐active robot‐assisted total hip arthroplasty (THA) has two options to measure the leg length discrepancy (LLD) and combined offset (CO), the 'enhanced' femoral workflow and the so‐called 'express' simplified workflow. The purpose of this study was to determine the precision and accuracy of intraoperative LLD and CO measurement with express workflow robotic THA. Methods: Between February 2018 and December 2019, 30 patients underwent an express workflow robot‐assisted primary THA for intraoperative LLD and CO measurements. Postoperative radiographs were used for LLD and CO measurement. In order to examine the accuracy of the robotic system assessment, the absolute difference between the robotic assessments and radiographic evaluations was calculated. Results: Intraoperative robotic measurements reported a mean error of 0.2–0.6 mm for each registration, with no significant difference between them ( p = 0.311). The average absolute discrepancies between the robotic and radiographic assessments in the LLD and CO measurements were 1.3 ± 1.5 mm ( p = 0.17) and 1.1 ± 0.9 mm ( p = 0.11), respectively, while the Pearson's correlation coefficients were 0.69 and 0.71. Conclusions: An external marker without a femoral array inserted into a screw positioned in the greater trochanter would be an easier and faster method to measure LLD and CO. Our study showed that the measured values of LLD and CO obtained by intraoperative express workflow robot‐assisted THAAbstract: Background: Semi‐active robot‐assisted total hip arthroplasty (THA) has two options to measure the leg length discrepancy (LLD) and combined offset (CO), the 'enhanced' femoral workflow and the so‐called 'express' simplified workflow. The purpose of this study was to determine the precision and accuracy of intraoperative LLD and CO measurement with express workflow robotic THA. Methods: Between February 2018 and December 2019, 30 patients underwent an express workflow robot‐assisted primary THA for intraoperative LLD and CO measurements. Postoperative radiographs were used for LLD and CO measurement. In order to examine the accuracy of the robotic system assessment, the absolute difference between the robotic assessments and radiographic evaluations was calculated. Results: Intraoperative robotic measurements reported a mean error of 0.2–0.6 mm for each registration, with no significant difference between them ( p = 0.311). The average absolute discrepancies between the robotic and radiographic assessments in the LLD and CO measurements were 1.3 ± 1.5 mm ( p = 0.17) and 1.1 ± 0.9 mm ( p = 0.11), respectively, while the Pearson's correlation coefficients were 0.69 and 0.71. Conclusions: An external marker without a femoral array inserted into a screw positioned in the greater trochanter would be an easier and faster method to measure LLD and CO. Our study showed that the measured values of LLD and CO obtained by intraoperative express workflow robot‐assisted THA system were precise and accurate. … (more)
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 16:Issue 5(2020)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 16:Issue 5(2020)
- Issue Display:
- Volume 16, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 16
- Issue:
- 5
- Issue Sort Value:
- 2020-0016-0005-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2020-08-19
- Subjects:
- combined offset -- express femoral workflow -- leg length discrepancy -- robot‐assisted technology -- total hip arthroplasty
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.2141 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14554.xml