Five‐minute whole‐heart coronary MRA with sub‐millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D‐PROST reconstruction. Issue 1 (29th July 2018)
- Record Type:
- Journal Article
- Title:
- Five‐minute whole‐heart coronary MRA with sub‐millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D‐PROST reconstruction. Issue 1 (29th July 2018)
- Main Title:
- Five‐minute whole‐heart coronary MRA with sub‐millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D‐PROST reconstruction
- Authors:
- Bustin, Aurélien
Ginami, Giulia
Cruz, Gastão
Correia, Teresa
Ismail, Tevfik F.
Rashid, Imran
Neji, Radhouene
Botnar, René M.
Prieto, Claudia - Abstract:
- Abstract : Purpose: To enable whole‐heart 3D coronary magnetic resonance angiography (CMRA) with isotropic sub‐millimeter resolution in a clinically feasible scan time by combining respiratory motion correction with highly accelerated variable density sampling in concert with a novel 3D patch‐based undersampled reconstruction (3D‐PROST). Methods: An undersampled variable density spiral‐like Cartesian trajectory was combined with 2D image‐based navigators to achieve 100% respiratory efficiency and predictable scan time. 3D‐PROST reconstruction integrates structural information from 3D patch neighborhoods through sparse representation, thereby exploiting the redundancy of the 3D anatomy of the coronary arteries in an efficient low‐rank formulation. The proposed framework was evaluated in a static resolution phantom and in 10 healthy subjects with isotropic resolutions of 1.2 mm 3 and 0.9 mm 3 and undersampling factors of ×5 and ×9. 3D‐PROST was compared against fully sampled (1.2 mm 3 only), conventional parallel imaging, and compressed sensing reconstructions. Results: Phantom and in vivo (1.2 mm 3 ) reconstructions were in excellent agreement with the reference fully sampled image. In vivo average acquisition times (min:s) were 7:57 ± 1:18 (×5) and 4:35 ± 0:44 (×9) for 0.9 mm 3 resolution. Sub‐millimeter 3D‐PROST resulted in excellent depiction of the left and right coronary arteries including small branch vessels, leading to further improvements in vessel sharpness andAbstract : Purpose: To enable whole‐heart 3D coronary magnetic resonance angiography (CMRA) with isotropic sub‐millimeter resolution in a clinically feasible scan time by combining respiratory motion correction with highly accelerated variable density sampling in concert with a novel 3D patch‐based undersampled reconstruction (3D‐PROST). Methods: An undersampled variable density spiral‐like Cartesian trajectory was combined with 2D image‐based navigators to achieve 100% respiratory efficiency and predictable scan time. 3D‐PROST reconstruction integrates structural information from 3D patch neighborhoods through sparse representation, thereby exploiting the redundancy of the 3D anatomy of the coronary arteries in an efficient low‐rank formulation. The proposed framework was evaluated in a static resolution phantom and in 10 healthy subjects with isotropic resolutions of 1.2 mm 3 and 0.9 mm 3 and undersampling factors of ×5 and ×9. 3D‐PROST was compared against fully sampled (1.2 mm 3 only), conventional parallel imaging, and compressed sensing reconstructions. Results: Phantom and in vivo (1.2 mm 3 ) reconstructions were in excellent agreement with the reference fully sampled image. In vivo average acquisition times (min:s) were 7:57 ± 1:18 (×5) and 4:35 ± 0:44 (×9) for 0.9 mm 3 resolution. Sub‐millimeter 3D‐PROST resulted in excellent depiction of the left and right coronary arteries including small branch vessels, leading to further improvements in vessel sharpness and visible vessel length in comparison with conventional reconstruction techniques. Image quality rated by 2 experts demonstrated that 3D‐PROST provides good image quality and is robust even at high acceleration factors. Conclusion: The proposed approach enables free‐breathing whole‐heart 3D CMRA with isotropic sub‐millimeter resolution in <5 min and achieves improved coronary artery visualization in a short and predictable scan time. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 1(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 1(2019)
- Issue Display:
- Volume 81, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 1
- Issue Sort Value:
- 2019-0081-0001-0000
- Page Start:
- 102
- Page End:
- 115
- Publication Date:
- 2018-07-29
- Subjects:
- accelerated imaging -- coronary MR angiography -- isotropic sub‐millimeter resolution -- patch reconstruction -- respiratory motion -- variable‐density undersampling
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27354 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14563.xml