When to include ECoG electrode properties in volume conduction models. (13th October 2020)
- Record Type:
- Journal Article
- Title:
- When to include ECoG electrode properties in volume conduction models. (13th October 2020)
- Main Title:
- When to include ECoG electrode properties in volume conduction models
- Authors:
- Vermaas, M
Piastra, M C
Oostendorp, T F
Ramsey, N F
Tiesinga, P H E - Abstract:
- Abstract: Objective. Implantable electrodes, such as electrocorticography (ECoG) grids, are used to record brain activity in applications like brain computer interfaces. To improve the spatial sensitivity of ECoG grid recordings, electrode properties need to be better understood. Therefore, the goal of this study is to analyze the importance of including electrodes explicitly in volume conduction calculations. Approach. We investigated the influence of ECoG electrode properties on potentials in three geometries with three different electrode models. We performed our simulations with FEMfuns, a volume conduction modeling software toolbox based on the finite element method. Main results. The presence of the electrode alters the potential distribution by an amount that depends on its surface impedance, its distance from the source and the strength of the source. Our modeling results show that when ECoG electrodes are near the sources the potentials in the underlying tissue are more uniform than without electrodes. We show that the recorded potential can change up to a factor of 3, if no extended electrode model is used. In conclusion, when the distance between an electrode and the source is equal to or smaller than the size of the electrode, electrode effects cannot be disregarded. Furthermore, the potential distribution of the tissue under the electrode is affected up to depths equal to the radius of the electrode. Significance. This paper shows the importance of explicitlyAbstract: Objective. Implantable electrodes, such as electrocorticography (ECoG) grids, are used to record brain activity in applications like brain computer interfaces. To improve the spatial sensitivity of ECoG grid recordings, electrode properties need to be better understood. Therefore, the goal of this study is to analyze the importance of including electrodes explicitly in volume conduction calculations. Approach. We investigated the influence of ECoG electrode properties on potentials in three geometries with three different electrode models. We performed our simulations with FEMfuns, a volume conduction modeling software toolbox based on the finite element method. Main results. The presence of the electrode alters the potential distribution by an amount that depends on its surface impedance, its distance from the source and the strength of the source. Our modeling results show that when ECoG electrodes are near the sources the potentials in the underlying tissue are more uniform than without electrodes. We show that the recorded potential can change up to a factor of 3, if no extended electrode model is used. In conclusion, when the distance between an electrode and the source is equal to or smaller than the size of the electrode, electrode effects cannot be disregarded. Furthermore, the potential distribution of the tissue under the electrode is affected up to depths equal to the radius of the electrode. Significance. This paper shows the importance of explicitly including electrode properties in volume conduction models for accurately interpreting ECoG measurements. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 17:Number 5(2020:Oct.)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 17:Number 5(2020:Oct.)
- Issue Display:
- Volume 17, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 17
- Issue:
- 5
- Issue Sort Value:
- 2020-0017-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10-13
- Subjects:
- finite element method -- ECoG -- electrode properties -- forward problem
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2552/abb11d ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14546.xml