A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices. (September 2020)
- Record Type:
- Journal Article
- Title:
- A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices. (September 2020)
- Main Title:
- A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices
- Authors:
- Wang, Yu
Peng, Jing
Rodefeld, Mark D.
Luan, Yong
Giridharan, Guruprasad A. - Abstract:
- Highlights: A new sensorless physiologic control algorithm for the Fontan pump was developed. A cavopulmonary pressure head was proposed to provide physiologic perfusion. The approach uses only intrinsic pump parameters and does not need external sensors. The proposed algorithm maintained physiologic perfusion while avoiding suction. Abstract: Objective: Mechanical circulatory support devices using continuous flow blood pump technologies are currently being developed to provide cavopulmonary support in patients with Fontan circulation. While cavopulmonary support can functionally replace the missing native right ventricle and biventricularize the Fontan circulation, there is a need for the pump to adapt to variable physiologic demands. A constant pump speed limits the ability to provide sufficient physiologic perfusion over a range of physiologic conditions. To address this challenge, a physiologic control algorithm for a Fontan pump was developed. Methods: The proposed algorithm uses a gain-scheduled, proportional-integral controller that generates a user defined cavopulmonary pressure head ( CPPH = pulmonary artery pressure - vena caval pressure), to provide physiologic pressure rise while avoiding suction. The approach uses only intrinsic pump parameters and does not require the use of pressure or flow sensors. Performance and robustness of the sensorless control algorithm was quantified in-silico by simulating the following conditions: (1) Directly measured CPPH withHighlights: A new sensorless physiologic control algorithm for the Fontan pump was developed. A cavopulmonary pressure head was proposed to provide physiologic perfusion. The approach uses only intrinsic pump parameters and does not need external sensors. The proposed algorithm maintained physiologic perfusion while avoiding suction. Abstract: Objective: Mechanical circulatory support devices using continuous flow blood pump technologies are currently being developed to provide cavopulmonary support in patients with Fontan circulation. While cavopulmonary support can functionally replace the missing native right ventricle and biventricularize the Fontan circulation, there is a need for the pump to adapt to variable physiologic demands. A constant pump speed limits the ability to provide sufficient physiologic perfusion over a range of physiologic conditions. To address this challenge, a physiologic control algorithm for a Fontan pump was developed. Methods: The proposed algorithm uses a gain-scheduled, proportional-integral controller that generates a user defined cavopulmonary pressure head ( CPPH = pulmonary artery pressure - vena caval pressure), to provide physiologic pressure rise while avoiding suction. The approach uses only intrinsic pump parameters and does not require the use of pressure or flow sensors. Performance and robustness of the sensorless control algorithm was quantified in-silico by simulating the following conditions: (1) Directly measured CPPH with pressure sensors; (2) CPPH estimation using the intrinsic pump measurement of pump speed and extended Kalman filter (EKF); (3) constant speed control algorithm; and (4) rapid four-fold increase in vena caval resistance (VCR) for (1) to (3). Results: The results demonstrated that the sensorless control algorithm maintained physiologic perfusion while simultaneously preventing vena caval suction without the need for pressure sensors. Conclusion and significance: The proposed algorithm was superior to the constant speed control strategy for physiologic perfusion and suction prevention, and warranted further investigation in vitro and in-vivo . … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 62(2020)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 62(2020)
- Issue Display:
- Volume 62, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 62
- Issue:
- 2020
- Issue Sort Value:
- 2020-0062-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Cavopulmonary circulatory support devices -- Fontan -- Sensorless physiologic control
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2020.102130 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14542.xml