Electrophysiological findings in patients with isolated veins after cryoablation for paroxysmal atrial fibrillation. Issue 9 (September 2020)
- Record Type:
- Journal Article
- Title:
- Electrophysiological findings in patients with isolated veins after cryoablation for paroxysmal atrial fibrillation. Issue 9 (September 2020)
- Main Title:
- Electrophysiological findings in patients with isolated veins after cryoablation for paroxysmal atrial fibrillation
- Authors:
- Varnavas, Varnavas
Terasawa, Muryo
Sieira, Juan
Abugattas, Juan Pablo
Ströker, Erwin
Paparella, Gaetano
Iacopino, Saverio
Maj, Riccardo
Osorio, Thiago Guimarães
De Greef, Yves
Bala, Gezim
Overeinder, Ingrid
Brugada, Pedro
de Asmundis, Carlo
Chierchia, Gian-Battista - Abstract:
- Abstract : Aims: The main cause of atrial fibrillation recurrence after catheter ablation is pulmonary vein reconnection. The purpose of this retrospective study was to analyse the electophysiological findings in patients undergoing repeat procedures after an index cryoballoon ablation (CB-A) and presenting with permanency of pulmonary vein isolation (PVI) in all veins. In addition, we sought to compare the latter with a similar group of patients with reconnected veins at the redo procedure. Methods: A total of 132 patients (81 men, 60.7 ± 12.4 years) who underwent CB-A for paroxysmal atrial fibrillation (PAF) were enrolled. Indication for the redo procedure was symptomatic PAF in 83 (63%), persistent atrial fibrillation (PerAF) in 32 (24%) or persistent regular atrial tachycardia (RAT) in 17 (13%) patients. Results: Seventy-five (57%) patients presented a pulmonary vein reconnection (pulmonary vein group) during the redo procedure, whereas 57 (43%) had no pulmonary vein reconnection (non-pulmonary vein group). The non-pulmonary vein group exhibited significantly more non-pulmonary vein foci and atrial flutters than the pulmonary vein group after induction protocol (51 vs. 24%, P = 0.002 and 67 vs. 36%, P = 0.003, respectively). Twenty-two (29.3%) patients of the pulmonary vein group and 20 (35%) patients of the non-pulmonary vein group had atrial fibrillation/RAT recurrence after a mean follow-up of 12.5 ± 8 months. The survival analysis demonstrated no statisticalAbstract : Aims: The main cause of atrial fibrillation recurrence after catheter ablation is pulmonary vein reconnection. The purpose of this retrospective study was to analyse the electophysiological findings in patients undergoing repeat procedures after an index cryoballoon ablation (CB-A) and presenting with permanency of pulmonary vein isolation (PVI) in all veins. In addition, we sought to compare the latter with a similar group of patients with reconnected veins at the redo procedure. Methods: A total of 132 patients (81 men, 60.7 ± 12.4 years) who underwent CB-A for paroxysmal atrial fibrillation (PAF) were enrolled. Indication for the redo procedure was symptomatic PAF in 83 (63%), persistent atrial fibrillation (PerAF) in 32 (24%) or persistent regular atrial tachycardia (RAT) in 17 (13%) patients. Results: Seventy-five (57%) patients presented a pulmonary vein reconnection (pulmonary vein group) during the redo procedure, whereas 57 (43%) had no pulmonary vein reconnection (non-pulmonary vein group). The non-pulmonary vein group exhibited significantly more non-pulmonary vein foci and atrial flutters than the pulmonary vein group after induction protocol (51 vs. 24%, P = 0.002 and 67 vs. 36%, P = 0.003, respectively). Twenty-two (29.3%) patients of the pulmonary vein group and 20 (35%) patients of the non-pulmonary vein group had atrial fibrillation/RAT recurrence after a mean follow-up of 12.5 ± 8 months. The survival analysis demonstrated no statistical significance in recurrence between both groups (log rank P = 0.358). Conclusion: Atrial fibrillation/RAT recurrence in patients after CB-A with durable PVI is significantly associated with non-pulmonary vein foci and atrial flutters. No statistically different success rate regarding atrial fibrillation/RAT freedom was detected between the pulmonary vein and non-pulmonary vein groups after redoing RF-CA. … (more)
- Is Part Of:
- Journal of cardiovascular medicine. Volume 21:Issue 9(2020:Sep.)
- Journal:
- Journal of cardiovascular medicine
- Issue:
- Volume 21:Issue 9(2020:Sep.)
- Issue Display:
- Volume 21, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 9
- Issue Sort Value:
- 2020-0021-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- atrial fibrillation -- cryoballoon -- non-pulmonary focus
Cardiology -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiology -- Periodicals
Cardiovascular Diseases -- Periodicals
616.1005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01244665-000000000-00000 ↗
http://www.jcardiovascularmedicine.com/pt/re/jcm/home.htm ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2459/JCM.0000000000001045 ↗
- Languages:
- English
- ISSNs:
- 1558-2027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.867300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14547.xml