Maintaining a high inspired oxygen fraction with the Elisée 350 turbine transport ventilator connected to two portable oxygen concentrators in an austere environment. Issue 3 (September 2020)
- Record Type:
- Journal Article
- Title:
- Maintaining a high inspired oxygen fraction with the Elisée 350 turbine transport ventilator connected to two portable oxygen concentrators in an austere environment. Issue 3 (September 2020)
- Main Title:
- Maintaining a high inspired oxygen fraction with the Elisée 350 turbine transport ventilator connected to two portable oxygen concentrators in an austere environment
- Authors:
- Cardinale, Michaël
Cungi, Pierre-Julien
Bordes, Julien
Cohergne, Fabien
Schmitt, Sarah
Langlois, Alix
Meaudre, Eric
Lacroix, Guillaume - Abstract:
- Abstract : BACKGROUND: Management of critically ill patients requiring mechanical ventilation in austere environments or during disaster response is a logistic challenge. Availability of oxygen cylinders for mechanically ventilated patient may be difficult in such a context. A solution to ventilate patients requiring high fraction of inspired oxygen (FiO2 ) is to use a ventilator able to be supplied by a low-pressure oxygen source connected with two oxygen concentrators (OCs). We tested the Elisée 350 (ResMedBella Vista, Australia) ventilator paired with two Newlife Intensity 10 (Airsep, Ball Ground, Georgia) OCs and evaluated the delivered FiO2 across a range of minute volumes and combinations of ventilator settings. METHODS: The ventilators were attached to a test lung, OC flow was adjusted with a Certifier FA ventilator test systems from 2 to 10 L/min and injected into the oxygen inlet port of the Elisée 350. The FiO2 was measured by the analyzer integrated in the ventilator, controlled by the ventilator test system. Several combinations of ventilator settings were evaluated to determine the factors affecting the delivered FiO2 . RESULTS: The Elisée 350 ventilator is a turbine ventilator able to deliver high FiO2 when functioning with two OCs. However, modifications of the ventilator settings such as an increase in minute ventilation affect delivered FiO2 even if oxygen flow is constant on the OC. CONCLUSION: The ability of two OCs to deliver high FiO2 when used with aAbstract : BACKGROUND: Management of critically ill patients requiring mechanical ventilation in austere environments or during disaster response is a logistic challenge. Availability of oxygen cylinders for mechanically ventilated patient may be difficult in such a context. A solution to ventilate patients requiring high fraction of inspired oxygen (FiO2 ) is to use a ventilator able to be supplied by a low-pressure oxygen source connected with two oxygen concentrators (OCs). We tested the Elisée 350 (ResMedBella Vista, Australia) ventilator paired with two Newlife Intensity 10 (Airsep, Ball Ground, Georgia) OCs and evaluated the delivered FiO2 across a range of minute volumes and combinations of ventilator settings. METHODS: The ventilators were attached to a test lung, OC flow was adjusted with a Certifier FA ventilator test systems from 2 to 10 L/min and injected into the oxygen inlet port of the Elisée 350. The FiO2 was measured by the analyzer integrated in the ventilator, controlled by the ventilator test system. Several combinations of ventilator settings were evaluated to determine the factors affecting the delivered FiO2 . RESULTS: The Elisée 350 ventilator is a turbine ventilator able to deliver high FiO2 when functioning with two OCs. However, modifications of the ventilator settings such as an increase in minute ventilation affect delivered FiO2 even if oxygen flow is constant on the OC. CONCLUSION: The ability of two OCs to deliver high FiO2 when used with a turbine ventilator makes this method of oxygen delivery a viable alternative to cylinders to ventilate patients requiring an FiO2 of ≥80% in austere place or during disaster response. LEVEL OF EVIDENCE: Feasibility study on test bench, level V. Abstract : Supplemental digital content is available in the text. … (more)
- Is Part Of:
- Journal of trauma and acute care surgery. Volume 89:Issue 3(2020)
- Journal:
- Journal of trauma and acute care surgery
- Issue:
- Volume 89:Issue 3(2020)
- Issue Display:
- Volume 89, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 89
- Issue:
- 3
- Issue Sort Value:
- 2020-0089-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- Oxygen concentrator -- portable ventilator -- fraction of inspired oxygen -- Austere environment -- COVID-19
Surgical intensive care -- Periodicals
Surgical emergencies -- Periodicals
Wounds and injuries -- Surgery -- Periodicals
617.026 - Journal URLs:
- http://journals.lww.com/jtrauma/pages/default.aspx ↗
http://ovidsp.tx.ovid.com/sp-3.5.0b/ovidweb.cgi?&S=NEIKFPIGHGDDBOHLNCALMDIBGLDKAA00&Browse=Toc+Children%7cNO%7cS.sh.2697_1327404888_15.2697_1327404888_27.2697_1327404888_28%7c273%7c50 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/TA.0000000000002792 ↗
- Languages:
- English
- ISSNs:
- 2163-0755
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5070.510500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14543.xml