Rates of Venous Thromboembolism and Central Line-Associated Bloodstream Infections Among Types of Central Venous Access Devices in Critically Ill Children*. Issue 9 (September 2020)
- Record Type:
- Journal Article
- Title:
- Rates of Venous Thromboembolism and Central Line-Associated Bloodstream Infections Among Types of Central Venous Access Devices in Critically Ill Children*. Issue 9 (September 2020)
- Main Title:
- Rates of Venous Thromboembolism and Central Line-Associated Bloodstream Infections Among Types of Central Venous Access Devices in Critically Ill Children*
- Authors:
- Patel, Nital
Petersen, Tara L.
Simpson, Pippa M.
Feng, Mingen
Hanson, Sheila J. - Abstract:
- Abstract : Objectives: Central venous access devices, including peripherally inserted central catheters and central venous catheters, are often needed in critically ill patients, but also are associated with complications, including central-line associated bloodstream infections and venous thromboembolism. We compared different central venous access device types and these complications in the PICU. Design: Multicenter, cohort study. Setting: One hundred forty-eight participating Virtual PICU Systems, LLC, hospital PICU sites. Patients: Pediatric patients with central venous access placed from January 1, 2010, to December 31, 2015. Interventions: None. Measurements and Main Results: Patient and central venous access device variables postulated to be associated with central-line associated bloodstream infection and venous thromboembolism were included. Data were analyzed using Pearson chi-square test or Fisher exact test for categorical variables, Mann-Whitney U test for continuous variables, and logistic regression and classification trees for multivariable analysis that examined significant predictors of venous thromboembolism or central-line associated bloodstream infection. Analysis included 74, 196 first lines including 4, 493 peripherally inserted central catheters and 66, 194 central venous catheters. An increased rate of venous thromboembolism (peripherally inserted central catheter: 0.93%, central venous catheter: 0.52%; p = 0.001) (peripherally inserted centralAbstract : Objectives: Central venous access devices, including peripherally inserted central catheters and central venous catheters, are often needed in critically ill patients, but also are associated with complications, including central-line associated bloodstream infections and venous thromboembolism. We compared different central venous access device types and these complications in the PICU. Design: Multicenter, cohort study. Setting: One hundred forty-eight participating Virtual PICU Systems, LLC, hospital PICU sites. Patients: Pediatric patients with central venous access placed from January 1, 2010, to December 31, 2015. Interventions: None. Measurements and Main Results: Patient and central venous access device variables postulated to be associated with central-line associated bloodstream infection and venous thromboembolism were included. Data were analyzed using Pearson chi-square test or Fisher exact test for categorical variables, Mann-Whitney U test for continuous variables, and logistic regression and classification trees for multivariable analysis that examined significant predictors of venous thromboembolism or central-line associated bloodstream infection. Analysis included 74, 196 first lines including 4, 493 peripherally inserted central catheters and 66, 194 central venous catheters. An increased rate of venous thromboembolism (peripherally inserted central catheter: 0.93%, central venous catheter: 0.52%; p = 0.001) (peripherally inserted central catheter: 8.65/1, 000 line days, central venous catheter: 6.29/1, 000 line days) and central-line associated bloodstream infection (peripherally inserted central catheter: 0.73%, central venous catheter: 0.24%; p = 0.001) (peripherally inserted central catheter: 10.82/1, 000 line days, central venous catheter: 4.97/1, 000 line days) occurred in peripherally inserted central catheters. In multivariable analysis, central venous catheters had decreased association with central-line associated bloodstream infection (odds ratio, 0.505; 95% CI, 0.336–0.759; p = 0.001) and venous thromboembolism (odds ratio, 0.569; 95% CI, 0.330–0.982; p = 0.043) compared with peripherally inserted central catheters. Conclusions: Peripherally inserted central catheters are associated with higher rates of central-line associated bloodstream infection and venous thromboembolism than central venous catheters in children admitted to the PICU. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 48:Issue 9(2020)
- Journal:
- Critical care medicine
- Issue:
- Volume 48:Issue 9(2020)
- Issue Display:
- Volume 48, Issue 9 (2020)
- Year:
- 2020
- Volume:
- 48
- Issue:
- 9
- Issue Sort Value:
- 2020-0048-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09
- Subjects:
- central venous catheters -- peripheral catheterization -- vascular access devices -- venous thromboembolism
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000004461 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14522.xml