Grating‐based phase contrast tomosynthesis imaging: Proof‐of‐concept experimental studies. Issue 1 (10th December 2013)
- Record Type:
- Journal Article
- Title:
- Grating‐based phase contrast tomosynthesis imaging: Proof‐of‐concept experimental studies. Issue 1 (10th December 2013)
- Main Title:
- Grating‐based phase contrast tomosynthesis imaging: Proof‐of‐concept experimental studies
- Authors:
- Li, Ke
Ge, Yongshuai
Garrett, John
Bevins, Nicholas
Zambelli, Joseph
Chen, Guang‐Hong - Abstract:
- Abstract : Purpose: : This paper concerns the feasibility of x‐ray differential phase contrast (DPC) tomosynthesis imaging using a grating‐based DPC benchtop experimental system, which is equipped with a commercial digital flat‐panel detector and a medical‐grade rotating‐anode x‐ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: : The major components of the benchtop system include a diagnostic x‐ray tube with a 1.0 mm nominal focal spot size, a flat‐panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot‐Lau interferometer with three x‐ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC‐tomo) reconstructed using the filtered‐backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC‐tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC‐tomo) reconstructed using the shift‐and‐add algorithm. Three inhouse physical phantoms containing tissue‐surrogate materials were used to characterize the signal linearity, the signal difference‐to‐noise ratio (SDNR), the three‐dimensional noise power spectrum (3D NPS), and the through‐plane artifact spread function (ASF). Results: : While DPC‐tomoAbstract : Purpose: : This paper concerns the feasibility of x‐ray differential phase contrast (DPC) tomosynthesis imaging using a grating‐based DPC benchtop experimental system, which is equipped with a commercial digital flat‐panel detector and a medical‐grade rotating‐anode x‐ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: : The major components of the benchtop system include a diagnostic x‐ray tube with a 1.0 mm nominal focal spot size, a flat‐panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot‐Lau interferometer with three x‐ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC‐tomo) reconstructed using the filtered‐backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC‐tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC‐tomo) reconstructed using the shift‐and‐add algorithm. Three inhouse physical phantoms containing tissue‐surrogate materials were used to characterize the signal linearity, the signal difference‐to‐noise ratio (SDNR), the three‐dimensional noise power spectrum (3D NPS), and the through‐plane artifact spread function (ASF). Results: : While DPC‐tomo highlights edges and interfaces in the image object, PC‐tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x‐ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC‐tomo, and the values were improved to 3.0 and 2.0, respectively, in PC‐tomo. PC‐tomo and AC‐tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS were found to be different due to the difference in the tomosynthesis image reconstruction algorithms. Conclusions: : It is feasible to simultaneously generate x‐ray differential phase contrast, phase contrast, and absorption contrast tomosynthesis images using a grating‐based data acquisition setup. The method shows promise in improving the visibility of several low‐density materials and therefore merits further investigation. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 1(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 1(2014)
- Issue Display:
- Volume 41, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 1
- Issue Sort Value:
- 2014-0041-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-12-10
- Subjects:
- Computed tomography -- Digital radiography -- Reconstruction -- Noise
biological tissues -- computerised tomography -- data acquisition -- diagnostic radiography -- diffraction gratings -- Hilbert transforms -- image reconstruction -- medical image processing -- phantoms -- refractive index -- X‐ray tubes
x‐ray phase contrast imaging -- Talbot‐Lau interferometer -- digital tomosynthesis
Computerised tomographs -- Biological material, e.g. blood, urine; Haemocytometers -- Diffracting gratings -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- X‐ray tubes
Digital tomosynthesis mammography -- Medical X‐ray imaging -- Medical image contrast -- X‐ray imaging -- Image reconstruction -- Medical image reconstruction -- Diffraction gratings -- Medical image noise
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4835455 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14518.xml