Odor dispersion modeling with CALPUFF: Case study of a waste and residue treatment incineration and utilization plant in Kocaeli, Turkey. Issue 1 (2nd January 2018)
- Record Type:
- Journal Article
- Title:
- Odor dispersion modeling with CALPUFF: Case study of a waste and residue treatment incineration and utilization plant in Kocaeli, Turkey. Issue 1 (2nd January 2018)
- Main Title:
- Odor dispersion modeling with CALPUFF: Case study of a waste and residue treatment incineration and utilization plant in Kocaeli, Turkey
- Authors:
- Çetin Doğruparmak, Şenay
Pekey, Hakan
Arslanbaş, Demet - Abstract:
- ABSTRACT: This study addresses the odor problem at a waste and residue treatment incineration and utilization plant located within the borders the Alikahya district of the Kocaeli province in Turkey. In the first stage of the study, odor measurements were made at designated sampling points, while in the second stage, odor concentrations were determined at the receptor points through dispersion modelling using a USEPA (United States Environmental Protection Agency) certified long-range (>50 km) CALPUFF lagrangian puff model. In the final stage, an analysis of the predicted and observed values was carried out using such statistical methods as geometric mean bias (MG), geometric variance (VG) and fractions of predictions within a factor of two observations (FAC2). During the modelling study, the highest one-hour concentration level was found to be 1868.10 OU (Odor Units), and the 24-hour concentration level was found to be 1316 OU, representing a decrease of approximately 30 percent. According to the measurement made, the maximum concentration value was 2455 OU. Odor measurements were carried out at 13 points within the area in order to assess the prediction results. When the results were assessed using the MG, VG and FAC2 statistical methods, it was observed that an acceptable model performance was not achieved for the whole sampling point. When the reason for this was investigated, it was concluded that the observed values were lower than the predicted values due to the factABSTRACT: This study addresses the odor problem at a waste and residue treatment incineration and utilization plant located within the borders the Alikahya district of the Kocaeli province in Turkey. In the first stage of the study, odor measurements were made at designated sampling points, while in the second stage, odor concentrations were determined at the receptor points through dispersion modelling using a USEPA (United States Environmental Protection Agency) certified long-range (>50 km) CALPUFF lagrangian puff model. In the final stage, an analysis of the predicted and observed values was carried out using such statistical methods as geometric mean bias (MG), geometric variance (VG) and fractions of predictions within a factor of two observations (FAC2). During the modelling study, the highest one-hour concentration level was found to be 1868.10 OU (Odor Units), and the 24-hour concentration level was found to be 1316 OU, representing a decrease of approximately 30 percent. According to the measurement made, the maximum concentration value was 2455 OU. Odor measurements were carried out at 13 points within the area in order to assess the prediction results. When the results were assessed using the MG, VG and FAC2 statistical methods, it was observed that an acceptable model performance was not achieved for the whole sampling point. When the reason for this was investigated, it was concluded that the observed values were lower than the predicted values due to the fact on the measurement days, the odor was dispersed by wind. It was further concluded that the observed values were higher than the predicted values as a result of odors emitted by other plants in the area. When the measurements in residential areas were examined to identify the effect of the odors, it was determined that although the primary density of settlement is to the southwest of the plant, it was not this area that was affected most, but rather the area to the northeast, where there is a lower settlement density. … (more)
- Is Part Of:
- Environmental forensics. Volume 19:Issue 1(2018)
- Journal:
- Environmental forensics
- Issue:
- Volume 19:Issue 1(2018)
- Issue Display:
- Volume 19, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 1
- Issue Sort Value:
- 2018-0019-0001-0000
- Page Start:
- 79
- Page End:
- 86
- Publication Date:
- 2018-01-02
- Subjects:
- Odor emission rate -- Odor dispersion -- CALPUFF model -- a waste and residue treatment incineration and utilization plant -- Kocaeli
Environmental forensics -- Periodicals
Pollution -- Measurement -- Periodicals
Environmental law -- Periodicals
Enquêtes environnementales -- Périodiques
363.25945 - Journal URLs:
- http://www.tandfonline.com/toc/uenf20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/15275922.2017.1408160 ↗
- Languages:
- English
- ISSNs:
- 1527-5922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.466300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14514.xml