Fast bilateral breast coverage with high spectral and spatial resolution (HiSS) MRI at 3T. Issue 5 (6th March 2017)
- Record Type:
- Journal Article
- Title:
- Fast bilateral breast coverage with high spectral and spatial resolution (HiSS) MRI at 3T. Issue 5 (6th March 2017)
- Main Title:
- Fast bilateral breast coverage with high spectral and spatial resolution (HiSS) MRI at 3T
- Authors:
- Medved, Milica
Li, Hui
Abe, Hiroyuki
Sheth, Deepa
Newstead, Gillian M.
Olopade, Olufunmilayo I.
Giger, Maryellen L.
Karczmar, Gregory S. - Abstract:
- Abstract : Purpose: To develop and assess a full‐coverage, sensitivity encoding (SENSE)‐accelerated breast high spatial and spectral resolution (HiSS) magnetic resonance imaging (MRI) within clinically reasonable times as a potential nonenhanced MRI protocol for breast density measurement or breast cancer screening. Materials and Methods: Sixteen women with biopsy‐proven cancer or suspicious lesions, and 13 women who were healthy volunteers or were screened for breast cancer, received 3T breast MRI exams, including SENSE‐accelerated HiSS MRI, which was implemented as a submillimeter spatial resolution echo‐planar spectroscopic imaging (EPSI) sequence. In postprocessing, fat and water resonance peak height and integral images were generated from EPSI data. The postprocessing software was custom‐designed, and new algorithms were developed to enable processing of whole‐coverage axial HiSS datasets. Water peak height HiSS images were compared to pre‐ and postcontrast T 1 ‐weighted images. Fat suppression was quantified as parenchymal‐to‐suppressed‐fat signal ratio in HiSS water peak height and nonenhanced T 1 ‐weighted images, and artifact levels were scored. Results: Approximately a 4‐fold decrease in acquisition speed, with a concurrent 2.5‐fold decrease in voxel size, was achieved, with low artifact levels, and with spectral signal‐to‐noise ratio (SNR) of 45:1. Fat suppression was 1.9 times more effective ( P < 0.001) in HiSS images than in T 1 ‐weighted images (SPAIR), andAbstract : Purpose: To develop and assess a full‐coverage, sensitivity encoding (SENSE)‐accelerated breast high spatial and spectral resolution (HiSS) magnetic resonance imaging (MRI) within clinically reasonable times as a potential nonenhanced MRI protocol for breast density measurement or breast cancer screening. Materials and Methods: Sixteen women with biopsy‐proven cancer or suspicious lesions, and 13 women who were healthy volunteers or were screened for breast cancer, received 3T breast MRI exams, including SENSE‐accelerated HiSS MRI, which was implemented as a submillimeter spatial resolution echo‐planar spectroscopic imaging (EPSI) sequence. In postprocessing, fat and water resonance peak height and integral images were generated from EPSI data. The postprocessing software was custom‐designed, and new algorithms were developed to enable processing of whole‐coverage axial HiSS datasets. Water peak height HiSS images were compared to pre‐ and postcontrast T 1 ‐weighted images. Fat suppression was quantified as parenchymal‐to‐suppressed‐fat signal ratio in HiSS water peak height and nonenhanced T 1 ‐weighted images, and artifact levels were scored. Results: Approximately a 4‐fold decrease in acquisition speed, with a concurrent 2.5‐fold decrease in voxel size, was achieved, with low artifact levels, and with spectral signal‐to‐noise ratio (SNR) of 45:1. Fat suppression was 1.9 times more effective ( P < 0.001) in HiSS images than in T 1 ‐weighted images (SPAIR), and HiSS images showed higher SNR in the axilla. HiSS MRI visualized 10 of 13 malignant lesions identified on dynamic contrast‐enhanced (DCE)‐MRI, and did not require skin removal in postprocessing to generate maximum intensity projection images. Conclusion: We demonstrate full‐coverage, SENSE‐accelerated breast HiSS MRI within clinically reasonable times, as a potential protocol for breast density measurement or breast cancer screening. Level of Evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1341–1348. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 5(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 5(2017)
- Issue Display:
- Volume 46, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 5
- Issue Sort Value:
- 2017-0046-0005-0000
- Page Start:
- 1341
- Page End:
- 1348
- Publication Date:
- 2017-03-06
- Subjects:
- high spatial and spectral resolution (HiSS) MRI -- echo planar spectroscopic imaging (EPSI) -- SENSE acceleration -- breast cancer screening and diagnosis -- breast density measurement
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25658 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14497.xml