Effect of Sonication Duration and Power on Ablation Depth During MR‐Guided Focused Ultrasound of Bone. Issue 5 (22nd February 2017)
- Record Type:
- Journal Article
- Title:
- Effect of Sonication Duration and Power on Ablation Depth During MR‐Guided Focused Ultrasound of Bone. Issue 5 (22nd February 2017)
- Main Title:
- Effect of Sonication Duration and Power on Ablation Depth During MR‐Guided Focused Ultrasound of Bone
- Authors:
- Bucknor, Matthew D.
Ozhinsky, Eugene
Shah, Rutwik
Krug, Roland
Rieke, Viola - Abstract:
- Abstract : Purpose: To evaluate the effect of differences in sonication duration and power on the size of postcontrast ablation zone following magnetic resonance‐guided focused ultrasound (MRgFUS) of bone in a swine femoral bone model. Materials and Methods: Experimental procedures received approval from the Institutional Committee on Animal Research. MRgFUS was used to create two thermal lesions in the left femur of six pigs. Each target was subjected to six sonications. 400J of energy was used for each sonication. However, the distal target received the standard sonication duration of 20 seconds (20W), while the proximal target received a longer sonication duration of 40 seconds (10W). MRgFUS lesions were imaged with fat‐saturated spoiled gradient echo sequence at 3.0T MRI 10 minutes following the administration of contrast. Maximum three‐plane dimensions of the hypoenhanced ablation area were measured. Results: Postcontrast MR images demonstrated ovoid regions of hypoenhancement at each target. The average depth of ablation was significantly greater for the shorter high‐power sonications (7.3 mm), compared to the longer lower‐power sonications (4.5 mm), P = 0.026. The craniocaudal dimension was also greater for the shorter ablations 26.7 mm compared to the longer sonications 21.0 mm, P = 0.006. Conclusion: Contrary to anecdotal clinical experience, this preclinical model suggests that during MRgFUS of bone, standard duration, higher‐power sonications resulted in deeperAbstract : Purpose: To evaluate the effect of differences in sonication duration and power on the size of postcontrast ablation zone following magnetic resonance‐guided focused ultrasound (MRgFUS) of bone in a swine femoral bone model. Materials and Methods: Experimental procedures received approval from the Institutional Committee on Animal Research. MRgFUS was used to create two thermal lesions in the left femur of six pigs. Each target was subjected to six sonications. 400J of energy was used for each sonication. However, the distal target received the standard sonication duration of 20 seconds (20W), while the proximal target received a longer sonication duration of 40 seconds (10W). MRgFUS lesions were imaged with fat‐saturated spoiled gradient echo sequence at 3.0T MRI 10 minutes following the administration of contrast. Maximum three‐plane dimensions of the hypoenhanced ablation area were measured. Results: Postcontrast MR images demonstrated ovoid regions of hypoenhancement at each target. The average depth of ablation was significantly greater for the shorter high‐power sonications (7.3 mm), compared to the longer lower‐power sonications (4.5 mm), P = 0.026. The craniocaudal dimension was also greater for the shorter ablations 26.7 mm compared to the longer sonications 21.0 mm, P = 0.006. Conclusion: Contrary to anecdotal clinical experience, this preclinical model suggests that during MRgFUS of bone, standard duration, higher‐power sonications resulted in deeper ablation volumes compared to long duration, lower‐power sonications. These results suggest that to achieve deeper ablations, if longer sonications are used, then the power should be relatively maintained, for a net energy increase. Level of Evidence: 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:1418–1422. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 46:Issue 5(2017)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 46:Issue 5(2017)
- Issue Display:
- Volume 46, Issue 5 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 5
- Issue Sort Value:
- 2017-0046-0005-0000
- Page Start:
- 1418
- Page End:
- 1422
- Publication Date:
- 2017-02-22
- Subjects:
- MR‐guided focused ultrasound -- high intensity focused ultrasound -- MRI -- bone ablation
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25676 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14497.xml