Angiographic, optical coherence tomography and histology findings from combination of a drug-coated balloon with an everolimus-eluting stent in a porcine model. (15th November 2016)
- Record Type:
- Journal Article
- Title:
- Angiographic, optical coherence tomography and histology findings from combination of a drug-coated balloon with an everolimus-eluting stent in a porcine model. (15th November 2016)
- Main Title:
- Angiographic, optical coherence tomography and histology findings from combination of a drug-coated balloon with an everolimus-eluting stent in a porcine model
- Authors:
- Ong, Paul J.L.
Kubo, Takashi
Watson, Timothy J.
Seah, Agnes S.P.
Wong, Philip E.H.
Akasaka, Takashi - Abstract:
- Abstract: Background: We designed a porcine model to compare the angiographic, optical coherence tomography (OCT) and histological findings of implanting an everolimus-eluting stent (EES) in the same segment of the coronary artery pre-treated with a drug-coating balloon (DCB; paccocath as carrier) with EES alone and DCB plus a bare metal stent (BMS). Methods: Seven female swine averaging 46.0 ± 2.4 kg were treated by random assignment as follows: DCB followed by EES; DCB followed by BMS; and EES alone. Quantitative coronary angiography (QCA) and OCT were carried out post-implantation and repeated after 28 ± 1 days. Results: All arteries remained patent and demonstrated no sign of thrombus formation. There was no significant difference at 1 month between the treatment groups in lumen loss (0.64 ± 0.43, 0.44 ± 0.43 and 0.33 ± 0.28 mm for EES, DCB/EES and DCB/BMS respectively, p = 0.37) and binary restenosis (6.86 (2.91–9.12), 4.93 (− 1.53–10.7) and 4.18 (3.27–10.2)% respectively, p = 0.87). OCT found mean neointimal thickness of 0.15 ± 0.09, 0.07 ± 0.03 and 0.08 ± 0.03 mm (p = 0.05) for EES, DCB/EES and DCB/BMS respectively. Endothelial strut coverage was 92.3 ± 5.5, 85.4 ± 8.6 and 89.1 ± 8.9% (p = 0.05) and mean neointimal area was 1.06 ± 0.42, 0.95 ± 0.24 and 1.20 ± 0.28 mm 2 (p = 0.09) respectively. Inflammation score was similar between the three groups: 0.20 (0.20–0.28), 0.30 (0.22–0.48), 0.30 (0.20–0.38) for EES, DCB/EES and DCB/BMS respectively (p = 0.14) and there wereAbstract: Background: We designed a porcine model to compare the angiographic, optical coherence tomography (OCT) and histological findings of implanting an everolimus-eluting stent (EES) in the same segment of the coronary artery pre-treated with a drug-coating balloon (DCB; paccocath as carrier) with EES alone and DCB plus a bare metal stent (BMS). Methods: Seven female swine averaging 46.0 ± 2.4 kg were treated by random assignment as follows: DCB followed by EES; DCB followed by BMS; and EES alone. Quantitative coronary angiography (QCA) and OCT were carried out post-implantation and repeated after 28 ± 1 days. Results: All arteries remained patent and demonstrated no sign of thrombus formation. There was no significant difference at 1 month between the treatment groups in lumen loss (0.64 ± 0.43, 0.44 ± 0.43 and 0.33 ± 0.28 mm for EES, DCB/EES and DCB/BMS respectively, p = 0.37) and binary restenosis (6.86 (2.91–9.12), 4.93 (− 1.53–10.7) and 4.18 (3.27–10.2)% respectively, p = 0.87). OCT found mean neointimal thickness of 0.15 ± 0.09, 0.07 ± 0.03 and 0.08 ± 0.03 mm (p = 0.05) for EES, DCB/EES and DCB/BMS respectively. Endothelial strut coverage was 92.3 ± 5.5, 85.4 ± 8.6 and 89.1 ± 8.9% (p = 0.05) and mean neointimal area was 1.06 ± 0.42, 0.95 ± 0.24 and 1.20 ± 0.28 mm 2 (p = 0.09) respectively. Inflammation score was similar between the three groups: 0.20 (0.20–0.28), 0.30 (0.22–0.48), 0.30 (0.20–0.38) for EES, DCB/EES and DCB/BMS respectively (p = 0.14) and there were no differences in fibrin deposition. Conclusions: The combination of DCB with EES appeared to be safe and effective. Using EES to bail out suboptimal DCB therapy appeared to be safe and effective in this porcine model. … (more)
- Is Part Of:
- International journal of cardiology. Volume 223(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 223(2016)
- Issue Display:
- Volume 223, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 223
- Issue:
- 2016
- Issue Sort Value:
- 2016-0223-2016-0000
- Page Start:
- 665
- Page End:
- 668
- Publication Date:
- 2016-11-15
- Subjects:
- Drug coated balloon -- Drug-eluting stent -- Everolimus -- Porcine coronary artery
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.08.268 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14493.xml