Evaluation of QMS Everolimus Assay Using Indiko Analyzer: Comparison With an Ultra-performance Liquid Chromatography–Tandem Mass Spectrometry Method. Issue 2 (April 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of QMS Everolimus Assay Using Indiko Analyzer: Comparison With an Ultra-performance Liquid Chromatography–Tandem Mass Spectrometry Method. Issue 2 (April 2015)
- Main Title:
- Evaluation of QMS Everolimus Assay Using Indiko Analyzer
- Authors:
- Buthiau, Delphine
Bargnoux, Anne-Sophie
Badiou, Stéphanie
Sutra, Thibault
Dupuy, Anne-Marie
Pageaux, Georges-Philippe
Mourad, Georges
Cristol, Jean-Paul - Abstract:
- Abstract : Background: A new particle-enhanced turbidimetric immunoassay, Quantitative Microsphere System (QMS) everolimus, was evaluated using an Indiko analyzer (Thermo Fisher Scientific). Methods: Analytical performances (imprecision, linearity, limit of detection, and limit of quantification) of this new immunoassay were evaluated. The method was compared with an ultra-performance liquid chromatography–tandem mass spectrometry (UPLC/MS/MS) method and with the previously available Innofluor Certican immunoassay on 120 whole-blood samples from 74 transplant recipients. Passing–Bablok regression and Bland–Altman plot were used for method comparisons. Results: Within- and between-day coefficients of variation were <10% at mean levels of 4.3, 8.2, and 15.9 ng/mL, respectively. This assay could be used at everolimus concentrations between 1.7 and 20 ng/mL. We obtained a Passing–Bablok regression of y = 0.99 × −0.15 (r = 0.95) when comparing with the UPLC/MS/MS method and of y = 0.81 × −0.09 (r = 0.94) when comparing with Innofluor assay. The mean and limits of agreement (mean ± 1.96 SD) of the difference between QMS everolimus and UPLC/MS/MS were −0.13 (from −2.0 to 1.74) ng/mL and were −1.19 (from −3.39 to 1.01) ng/mL between QMS everolimus and Innofluor. Conclusions: The QMS everolimus method on Indiko analyzer demonstrated reliable and reproducible performances allowing routine monitoring in transplant patients.
- Is Part Of:
- Therapeutic drug monitoring. Volume 37:Issue 2(2015:Apr.)
- Journal:
- Therapeutic drug monitoring
- Issue:
- Volume 37:Issue 2(2015:Apr.)
- Issue Display:
- Volume 37, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 37
- Issue:
- 2
- Issue Sort Value:
- 2015-0037-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-04
- Subjects:
- everolimus -- QMS immunoassay -- UPLC/MS/MS
Pharmacokinetics -- Periodicals
Patient monitoring -- Periodicals
Drugs -- Analysis -- Periodicals
Body fluids -- Analysis -- Periodicals
Drug Therapy -- Periodicals
Monitoring, Physiologic -- Periodicals
Pharmacology -- Periodicals
615.7 - Journal URLs:
- http://journals.lww.com/drug-monitoring/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00007691-000000000-00000 ↗
http://www.drug-monitoring.com/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0163-4356 ↗ - DOI:
- 10.1097/FTD.0000000000000133 ↗
- Languages:
- English
- ISSNs:
- 0163-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8814.643000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14500.xml