Single-factor and multifactor analysis of immune function and nucleic acid negative time in patients with COVID-19. (August 2020)
- Record Type:
- Journal Article
- Title:
- Single-factor and multifactor analysis of immune function and nucleic acid negative time in patients with COVID-19. (August 2020)
- Main Title:
- Single-factor and multifactor analysis of immune function and nucleic acid negative time in patients with COVID-19
- Authors:
- Fu, Hai-Yan
Li, Xiang
Li, Hong-Juan
Du, Ying-Rong
Zhou, Yu-Jun
Tang, Xiao-Qing
Jiao, Guan-Ping
Luo, Yu
Gao, Jian-Peng - Abstract:
- To analyse the differential indicators of COVID-19 in severe and mild cases and to study the factors affecting the immune function of patients and the time required for oropharyngeal swabs to become negative. Age, albumin (ALB) levels, prealbumin (PAB) levels, high-sensitivity C-reactive protein (hs-CRP) levels, platelet counts, lymphocyte counts, neutrophil counts, CD3+, CD4+, CD8+ T cell counts and the time for oropharyngeal swabs to become negative were collected from 37 patients with COVID-19; the neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) were calculated as indicators of inflammation. An independent-sample t test was used to analyse differences between the severe and mild groups, and factors affecting the CD3+, CD4+ and CD8+ T cell counts and the time for the nucleic acid tests of oropharyngeal to convert to negative were identified by single-factor and multifactor analyses. Lymphocyte, ALB, PAB, CD3+, CD4+ and CD8+ T cell levels in the severe group were lower than those in the mild group, the P values were 0.048, 0.004, 0.033, 0.033, 0.015 and 0.013, respectively. The neutrophil count and PLR were higher in the severe group compared with that in the patients of mild group; the P values were all 0.000. Single-factor analysis showed that age, ALB level, PAB level, hs-CRP level, platelet count, the NLR, the PLR and the time to a negative nucleic acid test were the main factors influencing CD3+ T cells; the P values were 0.001, 0.031,To analyse the differential indicators of COVID-19 in severe and mild cases and to study the factors affecting the immune function of patients and the time required for oropharyngeal swabs to become negative. Age, albumin (ALB) levels, prealbumin (PAB) levels, high-sensitivity C-reactive protein (hs-CRP) levels, platelet counts, lymphocyte counts, neutrophil counts, CD3+, CD4+, CD8+ T cell counts and the time for oropharyngeal swabs to become negative were collected from 37 patients with COVID-19; the neutrophil-to-lymphocyte ratio (NLR) and platelet-to-lymphocyte ratio (PLR) were calculated as indicators of inflammation. An independent-sample t test was used to analyse differences between the severe and mild groups, and factors affecting the CD3+, CD4+ and CD8+ T cell counts and the time for the nucleic acid tests of oropharyngeal to convert to negative were identified by single-factor and multifactor analyses. Lymphocyte, ALB, PAB, CD3+, CD4+ and CD8+ T cell levels in the severe group were lower than those in the mild group, the P values were 0.048, 0.004, 0.033, 0.033, 0.015 and 0.013, respectively. The neutrophil count and PLR were higher in the severe group compared with that in the patients of mild group; the P values were all 0.000. Single-factor analysis showed that age, ALB level, PAB level, hs-CRP level, platelet count, the NLR, the PLR and the time to a negative nucleic acid test were the main factors influencing CD3+ T cells; the P values were 0.001, 0.031, 0.001, 0.010, 0.005, 0.002, 0.000 and 0.048, respectively. Age, ALB level, PAB level, hs-CRP level, platelet count, the NLR, the PLR and time to a negative nucleic acid test were the main factors influencing CD8+ T cells; the P values were 0.000, 0.012, 0.000, 0.005, 0.002, 0.004, 0.005 and 0.003, respectively. Age, PAB level, hs-CRP level, platelet count, the NLR and the PLR were the main factors influencing CD4+ T cells; the P values were 0.001, 0.006, 0.030, 0.041, 0.005 and 0.001, respectively. Age, ALB level, PAB level, hs-CRP level, platelet count, the NLR, CD3+ T cell count and CD8+ T cell count were the main factors influencing the time to a negative nucleic acid test in oropharyngeal swabs, and the P values were 0.032, 0.043, 0.013, 0.016, 0.042, 0.049, 0.048 and 0.003, respectively. Multivariate analysis showed that the PLR and platelet count were the main factors influencing CD3+ T cells. The P values were all 0.000. The PLR and platelet count were the main factors influencing CD4+ T cells. The P values were 0.000 and 0.001, respectively. The PLR and platelet count were also the main factors influencing CD8+ T cells. The P values were 0.004 and 0.001. CD8+ T cells affected the time to a negative nucleic acid test in oropharyngeal swab samples, and the P value was 0.002. There were differences in the PLR, PAB level, ALB level and T cells between the severe and mild groups. The platelet count and PLR were the main factors influencing the immune function of patients with COVID-19, and CD8+ T cells influenced the negative conversion time of the nucleic acid test in oropharyngeal swabs. … (more)
- Is Part Of:
- European journal of inflammation. Volume 18(2020)
- Journal:
- European journal of inflammation
- Issue:
- Volume 18(2020)
- Issue Display:
- Volume 18, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 18
- Issue:
- 2020
- Issue Sort Value:
- 2020-0018-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08
- Subjects:
- COVID-19 -- factor -- immune function -- nucleic acid
Inflammation -- Periodicals
Anti-Inflammatory Agents -- therapeutic use -- Periodicals
Immunotherapy -- Periodicals
Inflammation -- Periodicals
Anti-inflammatory agents -- Periodicals
Immunotherapy -- Periodicals
Anti-inflammatory agents
Immunotherapy
Inflammation
Periodicals
616.0473 - Journal URLs:
- http://eji.sagepub.com/ ↗
http://www.biolifesas.org/blu.htm ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/2058739220935032 ↗
- Languages:
- English
- ISSNs:
- 1721-727X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14506.xml