Viability-qPCR for detecting Legionella: Comparison of two assays based on different amplicon lengths. Issue 4 (August 2015)
- Record Type:
- Journal Article
- Title:
- Viability-qPCR for detecting Legionella: Comparison of two assays based on different amplicon lengths. Issue 4 (August 2015)
- Main Title:
- Viability-qPCR for detecting Legionella: Comparison of two assays based on different amplicon lengths
- Authors:
- Ditommaso, Savina
Giacomuzzi, Monica
Ricciardi, Elisa
Zotti, Carla M. - Abstract:
- Abstract: Two different real-time quantitative PCR (PMA-qPCR) assays were applied for quantification of Legionella spp. by targeting a long amplicon (approx 400 bp) of 16S rRNA gene and a short amplicon (approx. 100 bp) of 5S rRNA gene. Purified DNA extracts from pure cultures of Legionella spp. and from environmental water samples were quantified. Application of the two assays to quantify Legionella in artificially contaminated water achieved that both assays were able to detect Legionella over a linear range of 10 to 10 5 cells ml −1 . A statistical analysis of the standard curves showed that both assays were linear with a good correlation coefficient (R 2 = 0.99) between the Ct and the copy number. Amplification with the reference assay was the most effective for detecting low copy numbers (1 bacterium per PCR mixture). Using selective quantification of viable Legionella by the PMA-qPCR method we obtained a greater inhibition of the amplification of the 400-bp 16S gene fragment (Δlog10 = 3.74 ± 0.39 log10 GU ml −1 ). A complete inhibition of the PCR signal was obtained when heat-killed cells in a concentration below 1 × 10 5 cells ml −1 were pretreated with PMA. Analysing short amplicon sizes led to only 2.08 log reductions in the Legionella dead-cell signal. When we tested environmental water samples, the two qPCR assays were in good agreement according to the kappa index (0.741). Applying qPCR combined with PMA treatment, we also obtained a good agreement (kappaAbstract: Two different real-time quantitative PCR (PMA-qPCR) assays were applied for quantification of Legionella spp. by targeting a long amplicon (approx 400 bp) of 16S rRNA gene and a short amplicon (approx. 100 bp) of 5S rRNA gene. Purified DNA extracts from pure cultures of Legionella spp. and from environmental water samples were quantified. Application of the two assays to quantify Legionella in artificially contaminated water achieved that both assays were able to detect Legionella over a linear range of 10 to 10 5 cells ml −1 . A statistical analysis of the standard curves showed that both assays were linear with a good correlation coefficient (R 2 = 0.99) between the Ct and the copy number. Amplification with the reference assay was the most effective for detecting low copy numbers (1 bacterium per PCR mixture). Using selective quantification of viable Legionella by the PMA-qPCR method we obtained a greater inhibition of the amplification of the 400-bp 16S gene fragment (Δlog10 = 3.74 ± 0.39 log10 GU ml −1 ). A complete inhibition of the PCR signal was obtained when heat-killed cells in a concentration below 1 × 10 5 cells ml −1 were pretreated with PMA. Analysing short amplicon sizes led to only 2.08 log reductions in the Legionella dead-cell signal. When we tested environmental water samples, the two qPCR assays were in good agreement according to the kappa index (0.741). Applying qPCR combined with PMA treatment, we also obtained a good agreement (kappa index 0.615). The comparison of quantitative results shows that both assays yielded the same quantification sensitivity (mean log = 4.59 vs mean log = 4.31). Highlights: We use two qPCR-PMA Legionella assays based on different amplicon length. We combined qPCR with PMA treatment to quantify heat killed Legionella cells. We use two qPCR-PMA assays to quantify viable Legionella in environmental samples. Biotechnology companies should develop assays to screen viable bacteria. … (more)
- Is Part Of:
- Molecular and cellular probes. Volume 29:Issue 4(2015)
- Journal:
- Molecular and cellular probes
- Issue:
- Volume 29:Issue 4(2015)
- Issue Display:
- Volume 29, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 4
- Issue Sort Value:
- 2015-0029-0004-0000
- Page Start:
- 237
- Page End:
- 243
- Publication Date:
- 2015-08
- Subjects:
- Legionella spp. -- PCR (polymerase chain reaction) -- Propidium monoazide -- Quantification -- Environmental water samples
Molecular probes -- Diagnostic use -- Periodicals
Pathology, Cellular -- Technique -- Periodicals
Cell Biology -- Periodicals
Molecular Biology -- Periodicals
Sondes moléculaires -- Utilisation diagnostique -- Périodiques
Cytopathologie -- Technique -- Périodiques
572 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08908508 ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0890-8508;screen=info;ECOIP ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.mcp.2015.05.011 ↗
- Languages:
- English
- ISSNs:
- 0890-8508
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5900.761000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14489.xml