Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup. (15th August 2016)
- Record Type:
- Journal Article
- Title:
- Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup. (15th August 2016)
- Main Title:
- Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup
- Authors:
- Alavi, Seyed Rashid
Rahmati, Mehdi - Abstract:
- Graphical abstract: Highlights: An innovative wind-creator setup is provided to implement intrinsic features of the wind. A twofold trend is exhibited by outputs with respect to the cross-wind variation. Influences of cross-wind velocity, inlet water temperature and water flow rate are studied. Regression analysis is utilized so as to develop general mathematical equations. A guideline is recommended for the purpose of reaching optimum operating conditions. Abstract: Natural draft wet cooling towers are one of the most widely-used types of wet cooling towers in the large-scale power plants. In the present research, the heat transfer performance of natural draft counter-flow wet cooling towers is investigated under cross-wind and windless conditions by virtue of an innovative wind-creator setup provided so as to implement intrinsic features of the natural wind speed profile precisely. As a matter of fact, this investigation will focus on the influences of cross-wind velocity, inlet water temperature and water flow rate on the water temperature difference and cooling efficiency of the studied cooling tower, with an emphasis on the role of wind speed features. Interestingly, a twofold trend is exhibited by the water temperature difference and cooling efficiency with respect to variation of the cross-wind velocity. Furthermore, to have a more applicable study, regression analysis of the experimental results is utilized for the sake of developing general mathematical equationsGraphical abstract: Highlights: An innovative wind-creator setup is provided to implement intrinsic features of the wind. A twofold trend is exhibited by outputs with respect to the cross-wind variation. Influences of cross-wind velocity, inlet water temperature and water flow rate are studied. Regression analysis is utilized so as to develop general mathematical equations. A guideline is recommended for the purpose of reaching optimum operating conditions. Abstract: Natural draft wet cooling towers are one of the most widely-used types of wet cooling towers in the large-scale power plants. In the present research, the heat transfer performance of natural draft counter-flow wet cooling towers is investigated under cross-wind and windless conditions by virtue of an innovative wind-creator setup provided so as to implement intrinsic features of the natural wind speed profile precisely. As a matter of fact, this investigation will focus on the influences of cross-wind velocity, inlet water temperature and water flow rate on the water temperature difference and cooling efficiency of the studied cooling tower, with an emphasis on the role of wind speed features. Interestingly, a twofold trend is exhibited by the water temperature difference and cooling efficiency with respect to variation of the cross-wind velocity. Furthermore, to have a more applicable study, regression analysis of the experimental results is utilized for the sake of developing general mathematical equations and thus facilitating further analyses. Finally, these mathematical equations are employed in order to recommend a guideline for the purpose of reaching optimum operating conditions of natural draft wet cooling towers. … (more)
- Is Part Of:
- Energy conversion and management. Volume 122(2016)
- Journal:
- Energy conversion and management
- Issue:
- Volume 122(2016)
- Issue Display:
- Volume 122, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 122
- Issue:
- 2016
- Issue Sort Value:
- 2016-0122-2016-0000
- Page Start:
- 504
- Page End:
- 514
- Publication Date:
- 2016-08-15
- Subjects:
- Natural draft wet cooling tower -- Heat and mass transfer -- Cross-wind conditions -- Natural wind speed profile -- Cooling efficiency -- Multiple regression analysis
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2016.06.016 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14470.xml