Magnetic solid phase extraction of polycyclic aromatic hydrocarbons and chlorophenols based on cyano-ionic liquid functionalized magnetic nanoparticles and their determination by HPLC-DAD. Issue 80 (15th August 2016)
- Record Type:
- Journal Article
- Title:
- Magnetic solid phase extraction of polycyclic aromatic hydrocarbons and chlorophenols based on cyano-ionic liquid functionalized magnetic nanoparticles and their determination by HPLC-DAD. Issue 80 (15th August 2016)
- Main Title:
- Magnetic solid phase extraction of polycyclic aromatic hydrocarbons and chlorophenols based on cyano-ionic liquid functionalized magnetic nanoparticles and their determination by HPLC-DAD
- Authors:
- Bakhshaei, Shabnam
Kamboh, Muhammad Afzal
Nodeh, Hamid Rashidi
Md Zain, Sharifuddin
Mahmad Rozi, Siti Khalijah
Mohamad, Sharifah
Mohammed Mohialdeen, Issam A. - Abstract:
- Abstract : The extraction of CPs & PAHs on MNP@CN/IL provides highly percent recovery with good precision and enrichment factor of i.e., 100 & 200 for CPs and PAHs respectively. Abstract : A magnetic solid-phase extraction (MSPE) procedure on the newly synthesized cyano-ionic liquid functionalized magnetic nanoparticles (MNP@CN/IL ) was established and validated for the separation/preconcentration of polycyclic aromatic hydrocarbons (PAHs) and chlorophenols (CPs) from water samples prior to their HPLC-DAD determination. The new magnetic (MNP@CN/IL) adsorbent was characterized by Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), elemental analysis (CHNS), energy-dispersive X-ray spectroscopy (EDX), vibrating sample magnetometry (VSM), thermal gravimetric analysis (TGA) and transmission electron microscopy (TEM). The proposed method showed preconcentrations of 200 and 100 with low limits of detection (LOD = 0.40–0.59 and 0.35–0.67 μg L −1 ) with linearity ranges from 0.1–100 and 3–100 μg L −1 for PAHs and CPs, respectively. The extraction recoveries from environmental samples (leachate and sludge from a landfill site) ranged from 89.50–110.2% and 80.67–112.7% for PAHs and CPs, respectively, with satisfactory precision (% RSD less than 5%). The combination of cyano group and ionic liquid on the surface of the MNPs enhanced the extraction efficiency which might be due to π–π interactions as well as electrostatic interactions.
- Is Part Of:
- RSC advances. Volume 6:Issue 80(2016)
- Journal:
- RSC advances
- Issue:
- Volume 6:Issue 80(2016)
- Issue Display:
- Volume 6, Issue 80 (2016)
- Year:
- 2016
- Volume:
- 6
- Issue:
- 80
- Issue Sort Value:
- 2016-0006-0080-0000
- Page Start:
- 77047
- Page End:
- 77058
- Publication Date:
- 2016-08-15
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/RA ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ra13702d ↗
- Languages:
- English
- ISSNs:
- 2046-2069
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8036.750300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14474.xml