Feasibility study of preoperative microvessel evaluation and characterization in perforator flaps using various modes of color‐coded duplex sonography (CCDS). Issue 7 (15th September 2020)
- Record Type:
- Journal Article
- Title:
- Feasibility study of preoperative microvessel evaluation and characterization in perforator flaps using various modes of color‐coded duplex sonography (CCDS). Issue 7 (15th September 2020)
- Main Title:
- Feasibility study of preoperative microvessel evaluation and characterization in perforator flaps using various modes of color‐coded duplex sonography (CCDS)
- Authors:
- Kehrer, Andreas
Lonic, Daniel
Heidekrueger, Paul
Bosselmann, Talia
Taeger, Christian D.
Lamby, Philipp
Kehrer, Michael
Jung, Ernst Michael
Prantl, Lukas
Platz Batista da Silva, Natascha - Abstract:
- Abstract: Background: Color‐coded duplex sonography (CCDS) is useful for perforator flap design showing the highest sensitivity in identifying microvessels. This prospective study evaluates the feasibility of different ultrasound (US) modes applied by the microsurgeon in daily practice suggesting quantifiable reference values. Methods: Twenty‐four patients aged between 17 and 68 years (mean 43.3 ± 14.2 years) with 18 anterolateral thigh (ALT) and 6 superficial circumflex iliac artery (SCIP) flaps were included. Indications were traumatic ( n = 12), infectious ( n = 6), ischemic ( n = 4), or tumor‐associated defects ( n = 2). Different US modes were evaluated regarding applicability using multifrequency linear probes (5–15 MHz). Vessels diameter, peak systolic velocity (PSV), end diastolic velocity (EDV), and resistance index (RI) were measured. Preoperative results were correlated to intraoperative findings. Results: In the examined patient group with 24 perforator flaps a 100% correlation was seen when comparing perforators detected with CCDS/PD with intraoperative findings using optimized US settings. Sensitivity, PPV, and accuracy of CCDS were 100% respectively. Mean PSV of 16.99 ± 6.07 cm/s, mean EDV of 5.01 ± 1.84 cm/s and RI of 0.7 ± 0.07 were measured in microvessels (PW‐mode). CCDS proved to be superior compared to PD in correct diameter assessment showing a mean diameter of 1.65 ± 0.45 mm, compared to PD‐mode 1.31 ± 0.24 mm. Mean PSV and EDV were higher in ALT thanAbstract: Background: Color‐coded duplex sonography (CCDS) is useful for perforator flap design showing the highest sensitivity in identifying microvessels. This prospective study evaluates the feasibility of different ultrasound (US) modes applied by the microsurgeon in daily practice suggesting quantifiable reference values. Methods: Twenty‐four patients aged between 17 and 68 years (mean 43.3 ± 14.2 years) with 18 anterolateral thigh (ALT) and 6 superficial circumflex iliac artery (SCIP) flaps were included. Indications were traumatic ( n = 12), infectious ( n = 6), ischemic ( n = 4), or tumor‐associated defects ( n = 2). Different US modes were evaluated regarding applicability using multifrequency linear probes (5–15 MHz). Vessels diameter, peak systolic velocity (PSV), end diastolic velocity (EDV), and resistance index (RI) were measured. Preoperative results were correlated to intraoperative findings. Results: In the examined patient group with 24 perforator flaps a 100% correlation was seen when comparing perforators detected with CCDS/PD with intraoperative findings using optimized US settings. Sensitivity, PPV, and accuracy of CCDS were 100% respectively. Mean PSV of 16.99 ± 6.07 cm/s, mean EDV of 5.01 ± 1.84 cm/s and RI of 0.7 ± 0.07 were measured in microvessels (PW‐mode). CCDS proved to be superior compared to PD in correct diameter assessment showing a mean diameter of 1.65 ± 0.45 mm, compared to PD‐mode 1.31 ± 0.24 mm. Mean PSV and EDV were higher in ALT than in SCIP flaps, RI was slightly higher in SCIP flaps ( p > .05). There were no significant differences in size of different flaps' perforators ( p > .05). Conclusion: CCDS represents a highly valuable tool in the daily practice of free flap reconstructions using optimized low flow US settings and multifrequency linear probes. … (more)
- Is Part Of:
- Microsurgery. Volume 40:Issue 7(2020)
- Journal:
- Microsurgery
- Issue:
- Volume 40:Issue 7(2020)
- Issue Display:
- Volume 40, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 40
- Issue:
- 7
- Issue Sort Value:
- 2020-0040-0007-0000
- Page Start:
- 750
- Page End:
- 759
- Publication Date:
- 2020-09-15
- Subjects:
- Microsurgery -- Periodicals
617.05 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1098-2752 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/micr.30648 ↗
- Languages:
- English
- ISSNs:
- 0738-1085
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.770000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14451.xml