Reliability of induced sputum test is greater than that of throat swab test for detecting SARS-CoV-2 in patients with COVID-19: A multi-center cross-sectional study. Issue 1 (1st January 2020)
- Record Type:
- Journal Article
- Title:
- Reliability of induced sputum test is greater than that of throat swab test for detecting SARS-CoV-2 in patients with COVID-19: A multi-center cross-sectional study. Issue 1 (1st January 2020)
- Main Title:
- Reliability of induced sputum test is greater than that of throat swab test for detecting SARS-CoV-2 in patients with COVID-19: A multi-center cross-sectional study
- Authors:
- Lai, Tianwen
Xiang, Fangfei
Zeng, Jianfeng
Huang, Yingzi
Jia, Liping
Chen, Hui
Wu, Jiayuan
Xie, Jianfeng
Liu, Shuna
Deng, Wei
Zheng, Weiqiang
Huang, Yang
Zhang, Qinfu
Luo, Qingfeng
Mo, Fan
Long, Lieming
Zhang, Wuying
Chen, Wenna
Han, Huanqin - Abstract:
- ABSTRACT: We previously reported that sputum induction was more sensitive than throat swabs for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in two convalescent coronavirus disease 2019 (COVID-19) patients; however, the value and safety of induced sputum testing require further study. We conducted a prospective multi-center cross-sectional study to compare induced sputum to throat swabs for SARS-CoV-2 detection. Confirmed COVID-19 patients from six hospitals in six cities across China who received one or more negative RT-PCR result for SARS-CoV-2 were enrolled, and paired specimens (induced sputum and throat swabs; 56 cases) were assayed. In three paired samples, both the induced sputum and throat swabs were positive for SARS-CoV-2. The positive rate for induced sputum was significantly higher than for throat swabs both overall (28.6% vs 5.4%, respectively; p < 0.01). Patients were divided according to time span from onset of illness to sample collection into the more-than-30-day (n = 26) and less-than-30-day (n = 30) groups. The positive rate for induced sputum was also significantly higher than for throat swabs in the less-than-30-day group (53.3% vs 10.0%, respectively; p < 0.001). For the more-than-30-day group, all paired samples were negative for SARS-CoV-2. Blood oxygen saturation, respiratory rate, and heart rate remained stable during sputum induction and no staff were infected. Because induced sputum is more reliable and has a lowerABSTRACT: We previously reported that sputum induction was more sensitive than throat swabs for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in two convalescent coronavirus disease 2019 (COVID-19) patients; however, the value and safety of induced sputum testing require further study. We conducted a prospective multi-center cross-sectional study to compare induced sputum to throat swabs for SARS-CoV-2 detection. Confirmed COVID-19 patients from six hospitals in six cities across China who received one or more negative RT-PCR result for SARS-CoV-2 were enrolled, and paired specimens (induced sputum and throat swabs; 56 cases) were assayed. In three paired samples, both the induced sputum and throat swabs were positive for SARS-CoV-2. The positive rate for induced sputum was significantly higher than for throat swabs both overall (28.6% vs 5.4%, respectively; p < 0.01). Patients were divided according to time span from onset of illness to sample collection into the more-than-30-day (n = 26) and less-than-30-day (n = 30) groups. The positive rate for induced sputum was also significantly higher than for throat swabs in the less-than-30-day group (53.3% vs 10.0%, respectively; p < 0.001). For the more-than-30-day group, all paired samples were negative for SARS-CoV-2. Blood oxygen saturation, respiratory rate, and heart rate remained stable during sputum induction and no staff were infected. Because induced sputum is more reliable and has a lower false-negative rate than throat swabs, we believe induced sputum is more useful for the confirmation of COVID-19 and is safer as a criterion for release from quarantine. … (more)
- Is Part Of:
- Virulence. Volume 11:Issue 1(2020)
- Journal:
- Virulence
- Issue:
- Volume 11:Issue 1(2020)
- Issue Display:
- Volume 11, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2020-0011-0001-0000
- Page Start:
- 1394
- Page End:
- 1401
- Publication Date:
- 2020-01-01
- Subjects:
- COVID-19 -- reliability -- induced sputum -- throat swab -- SARS-CoV-2
Virulence (Microbiology) -- Periodicals
Bacterial diseases -- Periodicals
Molecular microbiology -- Periodicals
579.05 - Journal URLs:
- http://www.landesbioscience.com/journals/virulence ↗
http://www.tandfonline.com/toc/kvir20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/21505594.2020.1831342 ↗
- Languages:
- English
- ISSNs:
- 2150-5608
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14440.xml