Solid phase extraction-based magnetic carbon nitride/metal organic framework composite with high performance liquid chromatography for the determination of tyrosine kinase inhibitors in urine samples. Issue 39 (21st September 2020)
- Record Type:
- Journal Article
- Title:
- Solid phase extraction-based magnetic carbon nitride/metal organic framework composite with high performance liquid chromatography for the determination of tyrosine kinase inhibitors in urine samples. Issue 39 (21st September 2020)
- Main Title:
- Solid phase extraction-based magnetic carbon nitride/metal organic framework composite with high performance liquid chromatography for the determination of tyrosine kinase inhibitors in urine samples
- Authors:
- Liu, Donghao
Peng, Jun
Chen, Li
Zhang, Yan
Han, Xiaoyang
Yang, Ping
He, Hua - Abstract:
- Abstract : Tyrosine kinase inhibitors were detected by MCN/BIF-20, and this is the first time that BIFs were used for solid-phase extraction. Abstract : In this study, a novel solid phase extraction method was constructed to detect three tyrosine kinase inhibitors (TKIs) in urine with a high-performance liquid chromatography-diode array detector. The sorbent MCN/BIF-20 was constructed by magnetic g-C3 N4 (MCN) and boron imidazole framework-20 (BIF-20) and was characterized by multiple techniques. The experimental results of the adsorption isotherm and adsorption kinetics indicated that the composites had good adsorption of TKIs (148.33 mg g −1, 283.25 mg g −1, 188.17 mg g −1 ). The reason for the good adsorption property of the complex material was revealed by comparison with each single material. The analytical method was built by a single factor experiment, and was evaluated as a suitable method to detect TKIs in urine by its good accuracy (90.35–98.69%), precision (<3.9%), appropriate detection limits (2.2–3.4 ng mL −1 ), and linear ranges (12.5–500 ng mL −1 ) with convenient determination coefficients (>0.9997). The performance of the MCN/BIF-20 composite did not decrease dramatically in 3 cycles. These analytical results demonstrated that g-C3 N4 and BIFs had a bright prospect in sample pretreatment, and the proposed approach based on MCN/BIF-20 was applicable for analysis of TKIs in urine.
- Is Part Of:
- Analytical methods. Volume 12:Issue 39(2020)
- Journal:
- Analytical methods
- Issue:
- Volume 12:Issue 39(2020)
- Issue Display:
- Volume 12, Issue 39 (2020)
- Year:
- 2020
- Volume:
- 12
- Issue:
- 39
- Issue Sort Value:
- 2020-0012-0039-0000
- Page Start:
- 4798
- Page End:
- 4805
- Publication Date:
- 2020-09-21
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0ay01243b ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14422.xml