Disinfection of contaminated metal implants with an Er:YAG laser. Issue 11 (24th March 2020)
- Record Type:
- Journal Article
- Title:
- Disinfection of contaminated metal implants with an Er:YAG laser. Issue 11 (24th March 2020)
- Main Title:
- Disinfection of contaminated metal implants with an Er:YAG laser
- Authors:
- Kriechbaumer, Lukas K.
Happak, Wolfgang
Distelmaier, Klaus
Thalhammer, Gerhild
Kaiser, Georg
Kugler, Sylvia
Tan, Yulong
Leonhard, Matthias
Zatorska, Beata
Presterl, Elisabeth
Nürnberger, Sylvia - Abstract:
- Abstract: Infections related to orthopedic procedures are considered particularly severe when implantation materials are used, because effective treatments for biofilm removal are lacking. In this study, the relatively new approach for infection control by using an erbium:yttrium‐aluminum‐garnet (Er:YAG) laser was tested. This laser vaporizes all water containing cells in a very effective, precise, and predictable manner and results in only minimal thermal damage. For preliminary testing, 42 steel plates and 42 pins were seeded with mixed cultures. First, the minimally necessary laser energy for biofilm removal was determined. Subsequently, the effectiveness of biofilm removal with the Er:YAG laser and the cleansing of the metal implants with octenidine‐soaked gauze was compared. Then, we compared the effectiveness of biofilm removal on 207 steel pins from 41 patients directly after explantation. Sonication and scanning electron microscopy were used for analysis. Laser fluences exceeding 2.8 J/cm 2 caused a complete extinction of all living cells by a single‐laser impulse. Cleansing with octenidine‐soaked gauze and irradiation with the Er:YAG laser are both thoroughly effective when applied to seeded pins. In contrast, when explanted pins with fully developed biofilms were analyzed, we found a significant advantage of the laser procedure. The Er:YAG laser offers a secure, complete, and nontoxic eradication of all kinds of pathogens from metal implants without damaging theAbstract: Infections related to orthopedic procedures are considered particularly severe when implantation materials are used, because effective treatments for biofilm removal are lacking. In this study, the relatively new approach for infection control by using an erbium:yttrium‐aluminum‐garnet (Er:YAG) laser was tested. This laser vaporizes all water containing cells in a very effective, precise, and predictable manner and results in only minimal thermal damage. For preliminary testing, 42 steel plates and 42 pins were seeded with mixed cultures. First, the minimally necessary laser energy for biofilm removal was determined. Subsequently, the effectiveness of biofilm removal with the Er:YAG laser and the cleansing of the metal implants with octenidine‐soaked gauze was compared. Then, we compared the effectiveness of biofilm removal on 207 steel pins from 41 patients directly after explantation. Sonication and scanning electron microscopy were used for analysis. Laser fluences exceeding 2.8 J/cm 2 caused a complete extinction of all living cells by a single‐laser impulse. Cleansing with octenidine‐soaked gauze and irradiation with the Er:YAG laser are both thoroughly effective when applied to seeded pins. In contrast, when explanted pins with fully developed biofilms were analyzed, we found a significant advantage of the laser procedure. The Er:YAG laser offers a secure, complete, and nontoxic eradication of all kinds of pathogens from metal implants without damaging the implant and without the possible development of resistance. The precise noncontact removal of adjacent tissue is a decisive advantage over conventional disinfectants. Therefore, laser irradiation could become a valuable method in every debridement, antibiotics, and implant retention procedure. … (more)
- Is Part Of:
- Journal of orthopaedic research. Volume 38:Issue 11(2020)
- Journal:
- Journal of orthopaedic research
- Issue:
- Volume 38:Issue 11(2020)
- Issue Display:
- Volume 38, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 38
- Issue:
- 11
- Issue Sort Value:
- 2020-0038-0011-0000
- Page Start:
- 2464
- Page End:
- 2473
- Publication Date:
- 2020-03-24
- Subjects:
- biofilm removal, DAIR -- Er:YAG laser -- implant‐related infection -- laser disinfection -- pin‐tract infection
Orthopedics -- Periodicals
Musculoskeletal system -- Periodicals
616.7 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jor.24662 ↗
- Languages:
- English
- ISSNs:
- 0736-0266
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.665000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14430.xml