Characterization of single channel liquid light guide coupling and SPAD array imaging for tumour margin estimation using fluorescence lifetime. (30th September 2020)
- Record Type:
- Journal Article
- Title:
- Characterization of single channel liquid light guide coupling and SPAD array imaging for tumour margin estimation using fluorescence lifetime. (30th September 2020)
- Main Title:
- Characterization of single channel liquid light guide coupling and SPAD array imaging for tumour margin estimation using fluorescence lifetime
- Authors:
- Stewart, Hazel L
Hungerford, Graham
Birch, David J S - Abstract:
- Abstract: Surgery remains one of the key treatment options for tumour removal, and surgeons primarily rely on eye and touch to assess the boundary between healthy and cancerous tissue with no cellular information as guidance. There is therefore a need for a device or instrument that can be used by the surgeon in real-time during the surgical procedure to ensure as many of the cancerous cells and as few of the healthy cells have been removed as possible. Fluorescence approaches have previously demonstrated significant promise in this application, but clinical take-up has been limited and much more characterization of critical parameters needed before robotic surgery can be contemplated. Here we investigate two time-correlated single-photon counting (TCSPC) fluorescence lifetime systems for the detection of phantom tumour margins derived from silica sol-gels. A simple and low-cost liquid light guide system (LLG) incorporating a single photomultiplier detection channel and translational stage was developed. This provided a useful reference for a compact single-photon avalanche diode (SPAD) array camera system for fluorescence lifetime imaging microscopy (FLIM) which permits up to ∼25 000 in-pixel timing measurements at video rates in ambient light using only low energy (∼30 pJ) diode laser pulses to minimize cell and dye degradation. Measurements of phantom margins with sol-gel doped Rhodamine 6G (R6G) of fluorescence lifetime ∼4 ns using the LLG system demonstrates that for 7Abstract: Surgery remains one of the key treatment options for tumour removal, and surgeons primarily rely on eye and touch to assess the boundary between healthy and cancerous tissue with no cellular information as guidance. There is therefore a need for a device or instrument that can be used by the surgeon in real-time during the surgical procedure to ensure as many of the cancerous cells and as few of the healthy cells have been removed as possible. Fluorescence approaches have previously demonstrated significant promise in this application, but clinical take-up has been limited and much more characterization of critical parameters needed before robotic surgery can be contemplated. Here we investigate two time-correlated single-photon counting (TCSPC) fluorescence lifetime systems for the detection of phantom tumour margins derived from silica sol-gels. A simple and low-cost liquid light guide system (LLG) incorporating a single photomultiplier detection channel and translational stage was developed. This provided a useful reference for a compact single-photon avalanche diode (SPAD) array camera system for fluorescence lifetime imaging microscopy (FLIM) which permits up to ∼25 000 in-pixel timing measurements at video rates in ambient light using only low energy (∼30 pJ) diode laser pulses to minimize cell and dye degradation. Measurements of phantom margins with sol-gel doped Rhodamine 6G (R6G) of fluorescence lifetime ∼4 ns using the LLG system demonstrates that for 7 mm excitation diameter and over 5–15 mm sol-gel LLG separation the sol-gel only region could be clearly identified 1 mm after the margin position, a widely accepted minimum surgical resolution. A comparison between measurements with the LLG and SPAD FLIM system using the sub-ns fluorescence lifetime of the FDA-approved dye indocyanine green (ICG) demonstrates that the minimum workable spatial resolution and sufficient speed are only achievable with such faster lifetimes using the SPAD FLIM system. … (more)
- Is Part Of:
- Measurement science & technology. Volume 31:Number 12(2020)
- Journal:
- Measurement science & technology
- Issue:
- Volume 31:Number 12(2020)
- Issue Display:
- Volume 31, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 12
- Issue Sort Value:
- 2020-0031-0012-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09-30
- Subjects:
- fluorescence lifetime -- FLIM -- silica sol-gel -- tissue phantom -- tumour margin estimation -- indocyanine green
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/aba5c6 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14406.xml