Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor. Issue 40 (2nd September 2020)
- Record Type:
- Journal Article
- Title:
- Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor. Issue 40 (2nd September 2020)
- Main Title:
- Sensitive and Stable 2D Perovskite Single‐Crystal X‐ray Detectors Enabled by a Supramolecular Anchor
- Authors:
- Li, Huayang
Song, Jinmei
Pan, Wanting
Xu, Daren
Zhu, Wan‐an
Wei, Haotong
Yang, Bai - Abstract:
- Abstract: Perovskite X‐ray detectors have been demonstrated to be sensitive to soft X‐rays (<80 keV) for potential medical imaging applications. However, developing X‐ray detectors that are stable and sensitive to hard X‐rays (80 to 120 keV) for practical medical imaging is highly desired. Here, a sensitive 2D fluorophenethylammonium lead iodide ((F‐PEA)2 PbI4 ) perovskite single‐crystal hard‐X‐ray detector from low‐cost solution processes is reported. Dipole interaction of organic ions promotes the ordering of benzene rings as well as the supramolecular electrostatic interaction between electron‐deficient F atoms with neighbor benzene rings. Supramolecular interactions serve as a supramolecular anchor to stabilize and tune the electronic properties of single crystals. The 2D (F‐PEA)2 PbI4 perovskite single crystal exhibits an intrinsic property with record bulk resistivity of 1.36 × 10 12 Ω cm, which brings a low device noise for hard X‐ray detection. Meanwhile, the ion‐migration phenomenon is effectively suppressed, even under the large applied bias of 200 V, by blocking the ion migration paths after anchoring. Consequently, the (F‐PEA)2 PbI4 single crystal detector yields a sensitivity of 3402 μC Gy −1 air cm −2 to 120 keVp hard X‐rays with lowest detectable X‐ray dose rate of 23 nGyair s −1, outperforming the dominating CsI scintillator of commercial digital radiography systems by acquiring clear X‐ray images under much lower dose rate. In addition, the detector showsAbstract: Perovskite X‐ray detectors have been demonstrated to be sensitive to soft X‐rays (<80 keV) for potential medical imaging applications. However, developing X‐ray detectors that are stable and sensitive to hard X‐rays (80 to 120 keV) for practical medical imaging is highly desired. Here, a sensitive 2D fluorophenethylammonium lead iodide ((F‐PEA)2 PbI4 ) perovskite single‐crystal hard‐X‐ray detector from low‐cost solution processes is reported. Dipole interaction of organic ions promotes the ordering of benzene rings as well as the supramolecular electrostatic interaction between electron‐deficient F atoms with neighbor benzene rings. Supramolecular interactions serve as a supramolecular anchor to stabilize and tune the electronic properties of single crystals. The 2D (F‐PEA)2 PbI4 perovskite single crystal exhibits an intrinsic property with record bulk resistivity of 1.36 × 10 12 Ω cm, which brings a low device noise for hard X‐ray detection. Meanwhile, the ion‐migration phenomenon is effectively suppressed, even under the large applied bias of 200 V, by blocking the ion migration paths after anchoring. Consequently, the (F‐PEA)2 PbI4 single crystal detector yields a sensitivity of 3402 μC Gy −1 air cm −2 to 120 keVp hard X‐rays with lowest detectable X‐ray dose rate of 23 nGyair s −1, outperforming the dominating CsI scintillator of commercial digital radiography systems by acquiring clear X‐ray images under much lower dose rate. In addition, the detector shows high operation stability under extremely high‐flux X‐ray irradiation. Abstract : F atoms in an organic spacer of a 2D perovskite enhance the supramolecular electrostatic interactions, serving as supramolecular anchors to stabilize single crystals. The corresponding optoelectronic properties are also improved. A fluorophenethylammonium lead iodide X‐ray detector exhibits stable and sensitive response to 120 keVp X‐rays; clear X‐ray images with detection limit of 23 nGy s −1 are demonstrated. … (more)
- Is Part Of:
- Advanced materials. Volume 32:Issue 40(2020)
- Journal:
- Advanced materials
- Issue:
- Volume 32:Issue 40(2020)
- Issue Display:
- Volume 32, Issue 40 (2020)
- Year:
- 2020
- Volume:
- 32
- Issue:
- 40
- Issue Sort Value:
- 2020-0032-0040-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-09-02
- Subjects:
- 120 keVp hard X‐rays -- 2D perovskite single crystals -- sensitive X‐ray detectors -- stable X‐ray imaging -- supramolecular interaction
Materials -- Periodicals
Chemical vapor deposition -- Periodicals
620.11 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4095 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/adma.202003790 ↗
- Languages:
- English
- ISSNs:
- 0935-9648
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0696.897800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14408.xml