Effects of bubble size on the gas–liquid mass transfer of bubble swarms with Sauter mean diameters of 0.38–4.88 mm in a co‐current upflow bubble column. Issue 11 (11th May 2020)
- Record Type:
- Journal Article
- Title:
- Effects of bubble size on the gas–liquid mass transfer of bubble swarms with Sauter mean diameters of 0.38–4.88 mm in a co‐current upflow bubble column. Issue 11 (11th May 2020)
- Main Title:
- Effects of bubble size on the gas–liquid mass transfer of bubble swarms with Sauter mean diameters of 0.38–4.88 mm in a co‐current upflow bubble column
- Authors:
- Wang, Zhengchao
Guo, Kai
Liu, Hui
Liu, Chunjiang
Geng, Yao
Lu, Zhe
Jiao, Boya
Chen, Dengyue - Abstract:
- Abstract: BACKGROUND: Bubble columns have found a wide range of application in biochemical industry. Mass transfer in the bubble column can be manipulated by adjusting the bubble size. Thus, for the design of bubble columns, it is necessary to investigate the behaviors of different‐sized bubbles. This work attempts to study the global hydrodynamic and mass transfer characteristics of bubble swarms with Sauter mean diameters ( d 32 ) of 0.38–4.88 mm, from microbubbles to millimeter‐sized bubbles, in a co‐current bubble column. RESULTS: The specific interfacial areas of the bubble swarms with d 32 of 0.38–1.47 (generated by ceramic membrane module) and 1.05–4.88 mm (generated by plate gas distributor) are 250–1100 and 7–270 m −1, respectively. The liquid‐side mass transfer coefficient ( k L ) of those two kinds of bubbles are (0.45–1.16) × 10 −4 and (0.58–7.65) × 10 −4 m s −1, respectively. CONCLUSION: Decreasing the bubble size can effectively increase the volumetric mass transfer coefficient ( k L a ), especially when the bubble size decreases to several micrometers. The major contribution to the mass transfer enhancement results from the increase of the specific interfacial area. Conversely, the k L decreases clearly. It is demonstrated that Higbieʼs and Frosslingʼs equations can approximate the k L of the bubble swarms with d 32 > 2 mm and d 32 < 2 mm in the bubble column, respectively. © 2020 Society of Chemical Industry
- Is Part Of:
- Journal of chemical technology & biotechnology. Volume 95:Issue 11(2020)
- Journal:
- Journal of chemical technology & biotechnology
- Issue:
- Volume 95:Issue 11(2020)
- Issue Display:
- Volume 95, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 95
- Issue:
- 11
- Issue Sort Value:
- 2020-0095-0011-0000
- Page Start:
- 2853
- Page End:
- 2867
- Publication Date:
- 2020-05-11
- Subjects:
- bubble column -- gas holdup -- specific interfacial area -- bubble size distribution -- mass transfer coefficient
Biotechnology -- Periodicals
Chemistry, Technical -- Periodicals
Chemical engineering -- Periodicals
Industries -- Environmental aspects -- Periodicals
660 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-4660 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jctb.6445 ↗
- Languages:
- English
- ISSNs:
- 0268-2575
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4957.089000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14411.xml