A POC device for on-the-spot detection of hexavalent chromium in wastewater. Issue 5 (October 2020)
- Record Type:
- Journal Article
- Title:
- A POC device for on-the-spot detection of hexavalent chromium in wastewater. Issue 5 (October 2020)
- Main Title:
- A POC device for on-the-spot detection of hexavalent chromium in wastewater
- Authors:
- Kumar, Nitesh
Madhwal, Devinder
Jain, V.K.
Suman, - Abstract:
- Graphical abstract: Highlights: A hand-held portable, point of care (POC) device for detection of Chromium in liquid medium. The method involves the detection of hexavalent chromium in water as well as biological samples using citrate-capped silver nanoparticle (C-AgNPs) leading to reduction of Cr(VI) to Cr (III). The device was tested and results were calibrated with flame AAS. The limit of detection (LOD) and limit of quantitation (LOQ) is 26 ppb and 79 ppb, respectively. Abstract: The present work describes a novel handheld pocket-friendly device for on the spot detection of chromium. The device gives not only qualitative but also the quantitative determination of chromium in environmental wastewater samples. The qualitative detection can be made visually by the naked eye while for the quantitative detection a colorimetric device has been fabricated in-house. The system comprises a source, sample holder, detector, and a microcontroller-processing unit with a display unit. The method involves the detection of hexavalent chromium Cr (VI) in aqueous systems by using citrate-capped silver nanoparticle (C-AgNPs) leading to a reduction of Cr (VI) to Cr (III). The citrate capped silver nanoparticles were synthesized and characterized using a blend of characterization techniques like ultra-violet visible (UV-Vis) spectrophotometry, scanning electron microscopy (SEM), transmission electron microscopy (TEM) and dynamic light scattering (DLS) techniques. The device performanceGraphical abstract: Highlights: A hand-held portable, point of care (POC) device for detection of Chromium in liquid medium. The method involves the detection of hexavalent chromium in water as well as biological samples using citrate-capped silver nanoparticle (C-AgNPs) leading to reduction of Cr(VI) to Cr (III). The device was tested and results were calibrated with flame AAS. The limit of detection (LOD) and limit of quantitation (LOQ) is 26 ppb and 79 ppb, respectively. Abstract: The present work describes a novel handheld pocket-friendly device for on the spot detection of chromium. The device gives not only qualitative but also the quantitative determination of chromium in environmental wastewater samples. The qualitative detection can be made visually by the naked eye while for the quantitative detection a colorimetric device has been fabricated in-house. The system comprises a source, sample holder, detector, and a microcontroller-processing unit with a display unit. The method involves the detection of hexavalent chromium Cr (VI) in aqueous systems by using citrate-capped silver nanoparticle (C-AgNPs) leading to a reduction of Cr (VI) to Cr (III). The citrate capped silver nanoparticles were synthesized and characterized using a blend of characterization techniques like ultra-violet visible (UV-Vis) spectrophotometry, scanning electron microscopy (SEM), transmission electron microscopy (TEM) and dynamic light scattering (DLS) techniques. The device performance remained unaffected even in the presence of various interfering cations present in the wastewater. The device was tested, and results were calibrated with standard atomic absorption spectroscopy (AAS), it showed linearity from 0.01-0.7 ppm for wastewater samples tested with spiking different known concentrations of chromium. The limit of detection (LOD) of the method is 26 ppb and the limit of quantitation (LOQ) of 79 ppb. The development of a low-cost, simple colorimeter employing the same sensor principle underlines the on-site applicability of this method. … (more)
- Is Part Of:
- Journal of environmental chemical engineering. Volume 8:Issue 5(2020)
- Journal:
- Journal of environmental chemical engineering
- Issue:
- Volume 8:Issue 5(2020)
- Issue Display:
- Volume 8, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 8
- Issue:
- 5
- Issue Sort Value:
- 2020-0008-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- Hand-held pocket-friendly device -- Chromium detection -- Qualitative & quantitative detection -- Colorimetric device -- Lab-on-chip
Chemical engineering -- Environmental aspects -- Periodicals
Environmental engineering -- Periodicals
Chemical engineering -- Environmental aspects
Environmental engineering
Periodicals
660.0286 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22133437 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jece.2020.104342 ↗
- Languages:
- English
- ISSNs:
- 2213-2929
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14396.xml