Multicentre Harmonisation of a Six-Colour Flow Cytometry Panel for Naïve/Memory T Cell Immunomonitoring. (28th March 2020)
- Record Type:
- Journal Article
- Title:
- Multicentre Harmonisation of a Six-Colour Flow Cytometry Panel for Naïve/Memory T Cell Immunomonitoring. (28th March 2020)
- Main Title:
- Multicentre Harmonisation of a Six-Colour Flow Cytometry Panel for Naïve/Memory T Cell Immunomonitoring
- Authors:
- Macchia, Iole
La Sorsa, Valentina
Ruspantini, Irene
Sanchez, Massimo
Tirelli, Valentina
Carollo, Maria
Fedele, Giorgio
Leone, Pasqualina
Schiavoni, Giovanna
Buccione, Carla
Rizza, Paola
Nisticò, Paola
Palermo, Belinda
Morrone, Stefania
Stabile, Helena
Rughetti, Aurelia
Nuti, Marianna
Zizzari, Ilaria Grazia
Fionda, Cinzia
Maggio, Roberta
Capuano, Cristina
Quintarelli, Concetta
Sinibaldi, Matilde
Agrati, Chiara
Casetti, Rita
Rozo Gonzalez, Andrea
Iacobone, Floriana
Gismondi, Angela
Belardelli, Filippo
Biffoni, Mauro
Urbani, Francesca
… (more) - Other Names:
- Hooper Douglas C. Academic Editor.
- Abstract:
- Abstract : Background . Personalised medicine in oncology needs standardised immunological assays. Flow cytometry (FCM) methods represent an essential tool for immunomonitoring, and their harmonisation is crucial to obtain comparable data in multicentre clinical trials. The objective of this study was to design a harmonisation workflow able to address the most effective issues contributing to intra- and interoperator variabilities in a multicentre project. Methods . The Italian National Institute of Health (Istituto Superiore di Sanità, ISS) managed a multiparametric flow cytometric panel harmonisation among thirteen operators belonging to five clinical and research centres of Lazio region (Italy). The panel was based on a backbone mixture of dried antibodies (anti-CD3, anti-CD4, anti-CD8, anti-CD45RA, and anti-CCR7) to detect naïve/memory T cells, recognised as potential prognostic/predictive immunological biomarkers in cancer immunotherapies. The coordinating centre distributed frozen peripheral blood mononuclear cells (PBMCs) and fresh whole blood (WB) samples from healthy donors, reagents, and Standard Operating Procedures (SOPs) to participants who performed experiments by their own equipment, in order to mimic a real-life scenario. Operators returned raw and locally analysed data to ISS for central analysis and statistical elaboration. Results . Harmonised and reproducible results were obtained by sharing experimental set-up and procedures along with centralising dataAbstract : Background . Personalised medicine in oncology needs standardised immunological assays. Flow cytometry (FCM) methods represent an essential tool for immunomonitoring, and their harmonisation is crucial to obtain comparable data in multicentre clinical trials. The objective of this study was to design a harmonisation workflow able to address the most effective issues contributing to intra- and interoperator variabilities in a multicentre project. Methods . The Italian National Institute of Health (Istituto Superiore di Sanità, ISS) managed a multiparametric flow cytometric panel harmonisation among thirteen operators belonging to five clinical and research centres of Lazio region (Italy). The panel was based on a backbone mixture of dried antibodies (anti-CD3, anti-CD4, anti-CD8, anti-CD45RA, and anti-CCR7) to detect naïve/memory T cells, recognised as potential prognostic/predictive immunological biomarkers in cancer immunotherapies. The coordinating centre distributed frozen peripheral blood mononuclear cells (PBMCs) and fresh whole blood (WB) samples from healthy donors, reagents, and Standard Operating Procedures (SOPs) to participants who performed experiments by their own equipment, in order to mimic a real-life scenario. Operators returned raw and locally analysed data to ISS for central analysis and statistical elaboration. Results . Harmonised and reproducible results were obtained by sharing experimental set-up and procedures along with centralising data analysis, leading to a reduction of cross-centre variability for naïve/memory subset frequencies particularly in the whole blood setting. Conclusion . Our experimental and analytical working process proved to be suitable for the harmonisation of FCM assays in a multicentre setting, where high-quality data are required to evaluate potential immunological markers, which may contribute to select better therapeutic options. … (more)
- Is Part Of:
- Journal of immunology research. Volume 2020(2020)
- Journal:
- Journal of immunology research
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03-28
- Subjects:
- Immunology -- Periodicals
Immunology -- Research -- Periodicals
616.07905 - Journal URLs:
- https://www.hindawi.com/journals/jir/ ↗
- DOI:
- 10.1155/2020/1938704 ↗
- Languages:
- English
- ISSNs:
- 2314-8861
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 14392.xml