The Impact of Self-Expandable Transcatheter Aortic Valve Replacement on Concomitant Functional Mitral Regurgitation: A Comprehensive Engineering Analysis. Issue 3 (3rd May 2020)
- Record Type:
- Journal Article
- Title:
- The Impact of Self-Expandable Transcatheter Aortic Valve Replacement on Concomitant Functional Mitral Regurgitation: A Comprehensive Engineering Analysis. Issue 3 (3rd May 2020)
- Main Title:
- The Impact of Self-Expandable Transcatheter Aortic Valve Replacement on Concomitant Functional Mitral Regurgitation: A Comprehensive Engineering Analysis
- Authors:
- Caballero, Andrés
Mao, Wenbin
McKay, Raymond
Sun, Wei - Abstract:
- ABSTRACT: Background: : Mitral regurgitation (MR) is present in a large proportion of patients who undergo transcatheter aortic valve replacement (TAVR). However, existing clinical data on the impact of TAVR on early post-procedural MR severity are contradictory. Using a comprehensive computational engineering methodology, this study aimed to quantitatively evaluate the structural and hemodynamic impact of TAVR on aortic-mitral continuity and MR severity in a rigorously developed and validated patient-specific left heart (LH) computer model with aortic stenosis and concomitant functional MR. Methods: : TAVR procedure was virtually simulated using a self-expandable valve (SEV) at three implantation heights. Pre- and post-TAVR LH dynamics as well as intra-operative biomechanics were analyzed. Results: : No significant differences in early MR improvement (<10%) were noted at the three implantation depths when compared to the pre-TAVR state. The high deployment model resulted in the highest stress in the native aortic leaflets, lowest stent-tissue contact force, highest aortic-mitral angle, and highest MR reduction for this patient case. When comparing SEV vs. balloon-expandable valve (BEV) performance at an optimal implantation height, the SEV gave a higher regurgitant volume than the pre-TAVR model (40.49 vs 37.59 ml), while the BEV model gave the lowest regurgitant volume (33.84 vs 37.59 ml). Conclusions: : Contact force, aortic-mitral angle, and valve annuli compression wereABSTRACT: Background: : Mitral regurgitation (MR) is present in a large proportion of patients who undergo transcatheter aortic valve replacement (TAVR). However, existing clinical data on the impact of TAVR on early post-procedural MR severity are contradictory. Using a comprehensive computational engineering methodology, this study aimed to quantitatively evaluate the structural and hemodynamic impact of TAVR on aortic-mitral continuity and MR severity in a rigorously developed and validated patient-specific left heart (LH) computer model with aortic stenosis and concomitant functional MR. Methods: : TAVR procedure was virtually simulated using a self-expandable valve (SEV) at three implantation heights. Pre- and post-TAVR LH dynamics as well as intra-operative biomechanics were analyzed. Results: : No significant differences in early MR improvement (<10%) were noted at the three implantation depths when compared to the pre-TAVR state. The high deployment model resulted in the highest stress in the native aortic leaflets, lowest stent-tissue contact force, highest aortic-mitral angle, and highest MR reduction for this patient case. When comparing SEV vs. balloon-expandable valve (BEV) performance at an optimal implantation height, the SEV gave a higher regurgitant volume than the pre-TAVR model (40.49 vs 37.59 ml), while the BEV model gave the lowest regurgitant volume (33.84 vs 37.59 ml). Conclusions: : Contact force, aortic-mitral angle, and valve annuli compression were identified as possible mechanistic parameters that may suggest avenues for acute MR improvement. Albeit a single patient parametric study, it is our hope that such detailed engineering analysis could shed some light into the underlying biomechanical mechanisms of TAVR impact on MR. … (more)
- Is Part Of:
- Structural heart. Volume 4:Issue 3(2020)
- Journal:
- Structural heart
- Issue:
- Volume 4:Issue 3(2020)
- Issue Display:
- Volume 4, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 4
- Issue:
- 3
- Issue Sort Value:
- 2020-0004-0003-0000
- Page Start:
- 179
- Page End:
- 191
- Publication Date:
- 2020-05-03
- Subjects:
- Aortic-mitral coupling -- mitral regurgitation -- transcatheter aortic valve replacement -- bicuspid aortic valve -- fluid-structure interaction -- echocardiography -- hemodynamics
Heart -- Diseases -- Periodicals
Congenital heart disease -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular Diseases
Cardiovascular system -- Diseases
Congenital heart disease
Heart -- Diseases
Periodicals
616.12 - Journal URLs:
- http://www.tandfonline.com/loi/ushj20 ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/24748706.2020.1740365 ↗
- Languages:
- English
- ISSNs:
- 2474-8706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14398.xml