Hybrid (2D/3D) Dosimetry of Radiolabeled Gold Nanoparticles for Sentinel Lymph Node Detection in Patients with Breast Cancer. (7th May 2020)
- Record Type:
- Journal Article
- Title:
- Hybrid (2D/3D) Dosimetry of Radiolabeled Gold Nanoparticles for Sentinel Lymph Node Detection in Patients with Breast Cancer. (7th May 2020)
- Main Title:
- Hybrid (2D/3D) Dosimetry of Radiolabeled Gold Nanoparticles for Sentinel Lymph Node Detection in Patients with Breast Cancer
- Authors:
- Ramírez-Nava, Gerardo
Santos-Cuevas, Clara
Ferro-Flores, Guillermina
Ocampo-García, Blanca
Chairez, Isaac
Gómez-Argumosa, Edgar
Abundiz-López, Lucero
García-Pérez, Francisco O. - Other Names:
- Herranz Fernando Academic Editor.
- Abstract:
- Abstract : Previously, we reported the preparation and preclinical studies of 99m Tc-labeled gold nanoparticles-mannose ( 99m Tc-AuNP-mannose) with potential for sentinel lymph node (SLN) detection by using nuclear medicine procedures. This study aimed to evaluate the biokinetics and hybrid (2D/3D) dosimetry of 99m Tc-AuNP-mannose in five patients with breast cancer under a sentinel lymph node detection protocol. Anterior and posterior whole-body planar images (2D, at 0.5, 2, 6, and 24 h) and single-photon emission computed tomography (3D at 6.5 h)/computed tomography (SPECT/CT) images were acquired after 99m Tc-AuNP-mannose administration (37 MBq). Through a hybrid quantification method, activity in tissues of interest at the different acquisition times was determined and integrated over time to obtain the total nuclear transformations ( N ), as well as the mean residence time, in each tissue. N values and the OLINDA code were used for estimating the internal radiation absorbed doses. Results demonstrated that 99m Tc-AuNP-mannose successfully accumulates and remains up to 24 h in the sentinel lymph node without detectable migration to other lymph nodes and no side effects on patients. Negligible absorption of the radiolabeled nanoparticles into the circulatory system was observed, from which the radio-nanosystem is rapidly eliminated by kidneys. Hybrid (2D/3D) dosimetry evaluations showed equivalent doses to SLN, breast, and kidneys of 172.34, 5.32, and 0.08 mSv/37 MBq,Abstract : Previously, we reported the preparation and preclinical studies of 99m Tc-labeled gold nanoparticles-mannose ( 99m Tc-AuNP-mannose) with potential for sentinel lymph node (SLN) detection by using nuclear medicine procedures. This study aimed to evaluate the biokinetics and hybrid (2D/3D) dosimetry of 99m Tc-AuNP-mannose in five patients with breast cancer under a sentinel lymph node detection protocol. Anterior and posterior whole-body planar images (2D, at 0.5, 2, 6, and 24 h) and single-photon emission computed tomography (3D at 6.5 h)/computed tomography (SPECT/CT) images were acquired after 99m Tc-AuNP-mannose administration (37 MBq). Through a hybrid quantification method, activity in tissues of interest at the different acquisition times was determined and integrated over time to obtain the total nuclear transformations ( N ), as well as the mean residence time, in each tissue. N values and the OLINDA code were used for estimating the internal radiation absorbed doses. Results demonstrated that 99m Tc-AuNP-mannose successfully accumulates and remains up to 24 h in the sentinel lymph node without detectable migration to other lymph nodes and no side effects on patients. Negligible absorption of the radiolabeled nanoparticles into the circulatory system was observed, from which the radio-nanosystem is rapidly eliminated by kidneys. Hybrid (2D/3D) dosimetry evaluations showed equivalent doses to SLN, breast, and kidneys of 172.34, 5.32, and 0.08 mSv/37 MBq, respectively, with an effective dose of 2.05 E − 03 mSv/MBq. The mean effective residence time in SLN was 0.92 h. This preliminary study indicates that the use of 99m Tc-AuNP-mannose for successful SLN detection in patients is safe, producing an effective dose at the level recommended for diagnostic studies (<10 mSv). … (more)
- Is Part Of:
- Contrast media & molecular imaging. Volume 2020(2020)
- Journal:
- Contrast media & molecular imaging
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-05-07
- Subjects:
- Diagnostic imaging -- Periodicals
Magnetic resonance imaging -- Periodicals
Contrast media (Diagnostic imaging) -- Periodicals
Contrast Media -- Periodicals
Diagnostic Imaging -- Periodicals
Substances de contraste -- Périodiques
Diagnostics moléculaires -- Périodiques
Imagerie médicale
Substance de contraste
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.0754 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/15554317 ↗
https://www.hindawi.com/journals/cmmi/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1155/2020/2728134 ↗
- Languages:
- English
- ISSNs:
- 1555-4309
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3426.351450
British Library HMNTS - ELD Digital store - Ingest File:
- 14377.xml