Initial Rotational Instability of the Tapered Wedge-Shaped Type Cementless Stem. (22nd September 2020)
- Record Type:
- Journal Article
- Title:
- Initial Rotational Instability of the Tapered Wedge-Shaped Type Cementless Stem. (22nd September 2020)
- Main Title:
- Initial Rotational Instability of the Tapered Wedge-Shaped Type Cementless Stem
- Authors:
- Iwamoto, Yosuke
Kijima, Hiroaki
Tazawa, Hiroshi
Konishi, Natsuo
Kubota, Hitoshi
Yamada, Shin
Tani, Takayuki
Kamo, Keiji
Suzuki, Norio
Okudera, Yoshihiko
Fujii, Masashi
Sasaki, Ken
Kawano, Tetsuya
Nagahata, Itsuki
Miyakoshi, Naohisa
Shimada, Yoichi - Other Names:
- Korovessis Panagiotis Academic Editor.
- Abstract:
- Abstract : Background . Because the tapered wedge-shaped type cementless stem has a small anteroposterior width and a low occupation rate in the medullary space, postoperative rotational instability and stem subsidence due to inadequate proximal fixation are concerns. The purpose of this study was to clarify the relationship between the rotational instability of the tapered wedge-shaped type cementless stem and femoral canal shape. Methods . A total of 61 primary total hip arthroplasties with the tapered wedge-shaped type cementless stem Accolade® TMZF (11 males, 50 females; mean age 60 years) from January 2012 to June 2015 who underwent computed tomography before surgery and within 4 weeks and 1 year after surgery were evaluated. The preoperative femoral neck anteversion angle, preoperative femoral canal flair index, the degree of postoperative stem subsidence within 1 year after operation, and the degree of rotational change in the stem setting angle within 1 year after operation were investigated. Results . The mean preoperative femoral neck anteversion angle was 32.2° ± 17.8° (0°–69°), and the mean preoperative canal flair index was 3.68 ± 0.58 (2.44–5.55). There were no stem subsidence cases within 1 year after operation. The mean degree of rotational change in the stem from immediately to 1 year after surgery was −0.4° ± 1.7° (−3°–3°). There was no significant correlation between the canal flair index and the rotational change in the stem. In addition, the meanAbstract : Background . Because the tapered wedge-shaped type cementless stem has a small anteroposterior width and a low occupation rate in the medullary space, postoperative rotational instability and stem subsidence due to inadequate proximal fixation are concerns. The purpose of this study was to clarify the relationship between the rotational instability of the tapered wedge-shaped type cementless stem and femoral canal shape. Methods . A total of 61 primary total hip arthroplasties with the tapered wedge-shaped type cementless stem Accolade® TMZF (11 males, 50 females; mean age 60 years) from January 2012 to June 2015 who underwent computed tomography before surgery and within 4 weeks and 1 year after surgery were evaluated. The preoperative femoral neck anteversion angle, preoperative femoral canal flair index, the degree of postoperative stem subsidence within 1 year after operation, and the degree of rotational change in the stem setting angle within 1 year after operation were investigated. Results . The mean preoperative femoral neck anteversion angle was 32.2° ± 17.8° (0°–69°), and the mean preoperative canal flair index was 3.68 ± 0.58 (2.44–5.55). There were no stem subsidence cases within 1 year after operation. The mean degree of rotational change in the stem from immediately to 1 year after surgery was −0.4° ± 1.7° (−3°–3°). There was no significant correlation between the canal flair index and the rotational change in the stem. In addition, the mean difference between the preoperative femoral neck anteversion angle and the stem rotational angle immediately after surgery was only 1.3° ± 5.3° (−29°–15°). Conclusions . In all cases, including stove-pipe cases, the degree of rotational change in the Accolade® TMZF stem from immediately to 1 year after surgery was within 3°. In other words, regardless of femoral canal shape, the tapered wedge-shaped type cementless stem has little initial rotational instability. … (more)
- Is Part Of:
- Advances in orthopedics. Volume 2020(2020)
- Journal:
- Advances in orthopedics
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09-22
- Subjects:
- Orthopedics -- Periodicals
Orthopedics
Orthopedic Procedures
Orthopedics
Electronic journals
Periodicals
Periodicals
616.7 - Journal URLs:
- https://www.hindawi.com/journals/aorth/ ↗
http://bibpurl.oclc.org/web/46477 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1600/ ↗
http://dx.doi.org/10.4061/aop ↗ - DOI:
- 10.1155/2020/2180260 ↗
- Languages:
- English
- ISSNs:
- 2090-3464
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 14376.xml