Improvement of kilovoltage intrafraction monitoring accuracy through gantry angles selection. (29th September 2020)
- Record Type:
- Journal Article
- Title:
- Improvement of kilovoltage intrafraction monitoring accuracy through gantry angles selection. (29th September 2020)
- Main Title:
- Improvement of kilovoltage intrafraction monitoring accuracy through gantry angles selection
- Authors:
- Vander Veken, Loïc
Dechambre, David
Michiels, Steven
Cohilis, Marie
Souris, Kevin
Lee, John Aldo
Geets, Xavier - Abstract:
- Abstract: Kilovoltage intrafraction monitoring (KIM) is a method allowing to precisely infer the tumour trajectory based on cone beam computed tomography (CBCT) 2D-projections. However, its accuracy is deteriorated in the case of highly mobile tumours involving hysteresis. A first adaptation of KIM consisting of a prior amplitude based binning step has been developed in order to minimize the errors of the original model (phase-KIM). In this work, we propose enhanced methods (KIMsub-arc optim and phase-KIMsub-arc optim ) to improve the accuracy of KIM and phase-KIM which relies on the selection of the optimal starting CBCT gantry angle. Aiming at demonstrating the interest of our approach, we carried out a simulation study and an experimental study: we compared the accuracy of the conventional versus sub-arc optim methods on simulated realistic tumour motions with amplitudes ranging from 5 to 30 mm in 1 mm increments. The same approach was performed using a lung dynamic phantom generating a 30 mm amplitude sinusoidal motion. The results show that for in-silico simulated motions of 10, 20 and 30 mm amplitude, the three-dimensional root mean square error (3D-RMSE) can be reduced by 0.67 mm, 0.91 mm, 0.94 mm and 0.18 mm, 0.25 mm, 0.28 mm using KIMsub-arc optim and phase-KIMsub-arc optim respectively. Considering all in-silico simulated trajectories, the percentage of errors larger than 1 mm decreases from 21.9% down to 1.6% for KIM (p < 0.001) and from 6.6% down to 1.2% forAbstract: Kilovoltage intrafraction monitoring (KIM) is a method allowing to precisely infer the tumour trajectory based on cone beam computed tomography (CBCT) 2D-projections. However, its accuracy is deteriorated in the case of highly mobile tumours involving hysteresis. A first adaptation of KIM consisting of a prior amplitude based binning step has been developed in order to minimize the errors of the original model (phase-KIM). In this work, we propose enhanced methods (KIMsub-arc optim and phase-KIMsub-arc optim ) to improve the accuracy of KIM and phase-KIM which relies on the selection of the optimal starting CBCT gantry angle. Aiming at demonstrating the interest of our approach, we carried out a simulation study and an experimental study: we compared the accuracy of the conventional versus sub-arc optim methods on simulated realistic tumour motions with amplitudes ranging from 5 to 30 mm in 1 mm increments. The same approach was performed using a lung dynamic phantom generating a 30 mm amplitude sinusoidal motion. The results show that for in-silico simulated motions of 10, 20 and 30 mm amplitude, the three-dimensional root mean square error (3D-RMSE) can be reduced by 0.67 mm, 0.91 mm, 0.94 mm and 0.18 mm, 0.25 mm, 0.28 mm using KIMsub-arc optim and phase-KIMsub-arc optim respectively. Considering all in-silico simulated trajectories, the percentage of errors larger than 1 mm decreases from 21.9% down to 1.6% for KIM (p < 0.001) and from 6.6% down to 1.2% for phase-KIM (p < 0.001). Experimentally, the 3D-RMSE is lowered by 0.5732 mm for KIM and by 0.1 mm for phase-KIM. The percentage of errors larger than 1 mm falls from 39.7% down to 18.5% for KIM and from 23.2% down to 11.1% for phase-KIM. In conclusion, our method efficiently anticipates CBCT gantry angles associated with a significantly better accuracy by using KIM and phase-KIM. … (more)
- Is Part Of:
- Biomedical physics & engineering express. Volume 6:Number 6(2020)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 6:Number 6(2020)
- Issue Display:
- Volume 6, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 6
- Issue:
- 6
- Issue Sort Value:
- 2020-0006-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-09-29
- Subjects:
- radiotherapy -- tumour motion -- intra-fraction imaging -- cone beam computed tomography
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/abb18e ↗