Clinical workflow for treating patients with a metallic hip prosthesis using magnetic resonance imaging-guided radiotherapy. (July 2020)
- Record Type:
- Journal Article
- Title:
- Clinical workflow for treating patients with a metallic hip prosthesis using magnetic resonance imaging-guided radiotherapy. (July 2020)
- Main Title:
- Clinical workflow for treating patients with a metallic hip prosthesis using magnetic resonance imaging-guided radiotherapy
- Authors:
- Keesman, Rick
van der Bijl, Erik
Janssen, Tomas M.
Vijlbrief, Tineke
Pos, Floris J.
van der Heide, Uulke A. - Abstract:
- Abstract: Background & purpose: Metallic prostheses distort the magnetic field during magnetic resonance imaging (MRI), leading to geometric distortions and signal loss. The purpose of this work was to develop a method to determine eligibility for MRI-guided radiotherapy (MRIgRT) on a per patient basis by estimating the magnitude of geometric distortions inside the clinical target volume (CTV). Materials & methods: Three patients with prostate cancer and hip prosthesis, treated using MRIgRT, were included. Eligibility for MRIgRT was based on computed tomography and associated CTV delineations, together with a field-distortion (B0) map and anatomical images acquired during MR simulation. To verify the method, B0 maps made during MR simulation and each MRIgRT treatment fraction were compared. Results: Estimates made during MR simulation of the magnitude of distortions inside the CTV were 0.43 mm, 0.19 mm and 2.79 mm compared to the average over all treatment fractions of 1.40 mm, 0.32 mm and 1.81 mm, per patient respectively. Conclusions: B0 map acquisitions prior to treatment can be used to estimate the magnitude of distortions during MRIgRT to guide the decision on eligibility for MRIgRT of prostate cancer patients with metallic hip implants.
- Is Part Of:
- Physics and imaging in radiation oncology. Volume 15(2020)
- Journal:
- Physics and imaging in radiation oncology
- Issue:
- Volume 15(2020)
- Issue Display:
- Volume 15, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 15
- Issue:
- 2020
- Issue Sort Value:
- 2020-0015-2020-0000
- Page Start:
- 85
- Page End:
- 90
- Publication Date:
- 2020-07
- Subjects:
- Distortion -- Prosthesis -- Implant -- MRIgRT -- MRgRT -- MR-linac
Radiotherapy -- Periodicals
Radiation dosimetry -- Periodicals
Cancer -- Imaging -- Periodicals
Oncology -- Periodicals
615.842 - Journal URLs:
- http://www.sciencedirect.com/ ↗
https://www.journals.elsevier.com/physics-and-imaging-in-radiation-oncology/ ↗ - DOI:
- 10.1016/j.phro.2020.07.010 ↗
- Languages:
- English
- ISSNs:
- 2405-6316
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14367.xml