Diagnosis of Gestational Diabetes Mellitus with Point-of-Care Methods for Glucose versus Hospital Laboratory Method Using Isotope Dilution Gas Chromatography-Mass Spectrometry as Reference. (21st March 2020)
- Record Type:
- Journal Article
- Title:
- Diagnosis of Gestational Diabetes Mellitus with Point-of-Care Methods for Glucose versus Hospital Laboratory Method Using Isotope Dilution Gas Chromatography-Mass Spectrometry as Reference. (21st March 2020)
- Main Title:
- Diagnosis of Gestational Diabetes Mellitus with Point-of-Care Methods for Glucose versus Hospital Laboratory Method Using Isotope Dilution Gas Chromatography-Mass Spectrometry as Reference
- Authors:
- Kristensen, Karl
Wangel, Anne-Marie
Katsarou, Anastasia
Shaat, Nael
Simmons, David
Fadl, Helena
Berntorp, Kerstin - Other Names:
- Calafiore Riccardo Academic Editor.
- Abstract:
- Abstract : Background . In Sweden, both glucose analyzers in accredited laboratories and point-of-care glucose devices are used for gestational diabetes mellitus (GDM) diagnosis. The aim of this study was to compare the diagnostic performance of the HemoCue Glucose 201+ (HC201+) and RT (HC201RT) systems with that of the hospital central laboratory hexokinase method (CL) based on lyophilized citrate tubes, using the isotope dilution gas chromatography-mass spectrometry (ID GC-MS) as reference. Methods . A 75 g oral glucose tolerance test was performed on 135 women screened positive for GDM. Diagnosis was based on the World Health Organization 2013 diagnostic thresholds for fasting (n = 135 ), 1 h (n = 52 ), and 2 h (n = 135 ) glucose measurements. Bland-Altman analysis and surveillance error grids were used to evaluate analytical and clinical accuracy. Results . Significantly more women were diagnosed with GDM by HC201+ (80%) and CL (80%) than with the reference (65%, P < 0.001 ) based on fasting and/or 2 h thresholds, whereas the percentage diagnosed by HC201RT (60%) did not differ significantly from the reference. In Bland-Altman analysis, a positive bias was observed for HC201+ (4.2%) and CL (6.1%) and a negative bias for HC201RT (−1.8%). In the surveillance error grid, 95.9% of the HC201+ values were in the no-risk zone as compared to 98.1% for HC201RT and 97.5% for CL. Conclusions . A substantial positive bias was found for CL measurements resulting in overdiagnosis ofAbstract : Background . In Sweden, both glucose analyzers in accredited laboratories and point-of-care glucose devices are used for gestational diabetes mellitus (GDM) diagnosis. The aim of this study was to compare the diagnostic performance of the HemoCue Glucose 201+ (HC201+) and RT (HC201RT) systems with that of the hospital central laboratory hexokinase method (CL) based on lyophilized citrate tubes, using the isotope dilution gas chromatography-mass spectrometry (ID GC-MS) as reference. Methods . A 75 g oral glucose tolerance test was performed on 135 women screened positive for GDM. Diagnosis was based on the World Health Organization 2013 diagnostic thresholds for fasting (n = 135 ), 1 h (n = 52 ), and 2 h (n = 135 ) glucose measurements. Bland-Altman analysis and surveillance error grids were used to evaluate analytical and clinical accuracy. Results . Significantly more women were diagnosed with GDM by HC201+ (80%) and CL (80%) than with the reference (65%, P < 0.001 ) based on fasting and/or 2 h thresholds, whereas the percentage diagnosed by HC201RT (60%) did not differ significantly from the reference. In Bland-Altman analysis, a positive bias was observed for HC201+ (4.2%) and CL (6.1%) and a negative bias for HC201RT (−1.8%). In the surveillance error grid, 95.9% of the HC201+ values were in the no-risk zone as compared to 98.1% for HC201RT and 97.5% for CL. Conclusions . A substantial positive bias was found for CL measurements resulting in overdiagnosis of GDM. Our findings suggest better performance of HC201RT than HC201+ in GDM diagnosis. The results may have possible implications for GDM diagnosis in Sweden and require further elucidation. … (more)
- Is Part Of:
- Journal of diabetes research. Volume 2020(2020)
- Journal:
- Journal of diabetes research
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03-21
- Subjects:
- Diabetes -- Periodicals
Diabetes -- Pathophysiology -- Periodicals
Diabetes -- Prevention -- Periodicals
Diabetes -- Etiology -- Periodicals
Diabetes -- Epidemiology -- Periodicals
Diabetes -- Pathogenesis -- Periodicals
616.462005 - Journal URLs:
- https://www.hindawi.com/journals/jdr/ ↗
- DOI:
- 10.1155/2020/7937403 ↗
- Languages:
- English
- ISSNs:
- 2314-6745
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 14339.xml