FIGO postpartum intrauterine device initiative: Complication rates across six countries. (18th September 2018)
- Record Type:
- Journal Article
- Title:
- FIGO postpartum intrauterine device initiative: Complication rates across six countries. (18th September 2018)
- Main Title:
- FIGO postpartum intrauterine device initiative: Complication rates across six countries
- Authors:
- Makins, Anita
Taghinejadi, Neda
Sethi, Maya
Machiyama, Kazuyo
Munganyizi, Projestine
Odongo, Elly
Divakar, Hema
Fatima, Parveen
Thapa, Kusum
Perera, Gamini
Arulkumaran, Sabaratnam - Abstract:
- Abstract: Objective: To record and analyze complication rates following postpartum intrauterine device (PPIUD) insertion in 48 hospitals in six countries: Sri Lanka, India, Nepal, Bangladesh, Tanzania, and Kenya. Methods: Healthcare providers were trained in counselling and insertion of PPIUD via a training‐the‐trainer model. Data were collected on methodology, timing, cadre of staff providing care, and number of insertions. Data on complications were collected at 6‐week follow‐up. Statistical analysis was performed to elucidate factors associated with increased expulsion and absence of threads. Results: From May 2014 to September 2017, 36 766 PPIUDs were inserted: 53% vaginal and 47% at cesarean delivery; 74% were inserted by doctors. Follow‐up was attended by 52%. Expulsion and removal rates were 2.5% and 3.6%, respectively. Threads were not visible in 29%. Expulsion was less likely after cesarean insertion (aOR 0.33; 95% CI, 0.26–0.41), following vaginal insertion at between 10 minutes and 48 hours (aOR 0.59; 95% CI, 0.42–0.83), and when insertion was performed by a nurse (aOR 0.33; 95% CI, 0.22–0.50). Conclusion: PPIUD has low complication rates and can be safely inserted by a variety of trained health staff. Given the immediate benefit of the one‐stop approach, governments should urgently consider adopting this model. Abstract : The FIGO PPIUD initiative demonstrated expulsion and removal rates of under 5% after follow‐up of 52% of 36 766 PPIUD insertions acrossAbstract: Objective: To record and analyze complication rates following postpartum intrauterine device (PPIUD) insertion in 48 hospitals in six countries: Sri Lanka, India, Nepal, Bangladesh, Tanzania, and Kenya. Methods: Healthcare providers were trained in counselling and insertion of PPIUD via a training‐the‐trainer model. Data were collected on methodology, timing, cadre of staff providing care, and number of insertions. Data on complications were collected at 6‐week follow‐up. Statistical analysis was performed to elucidate factors associated with increased expulsion and absence of threads. Results: From May 2014 to September 2017, 36 766 PPIUDs were inserted: 53% vaginal and 47% at cesarean delivery; 74% were inserted by doctors. Follow‐up was attended by 52%. Expulsion and removal rates were 2.5% and 3.6%, respectively. Threads were not visible in 29%. Expulsion was less likely after cesarean insertion (aOR 0.33; 95% CI, 0.26–0.41), following vaginal insertion at between 10 minutes and 48 hours (aOR 0.59; 95% CI, 0.42–0.83), and when insertion was performed by a nurse (aOR 0.33; 95% CI, 0.22–0.50). Conclusion: PPIUD has low complication rates and can be safely inserted by a variety of trained health staff. Given the immediate benefit of the one‐stop approach, governments should urgently consider adopting this model. Abstract : The FIGO PPIUD initiative demonstrated expulsion and removal rates of under 5% after follow‐up of 52% of 36 766 PPIUD insertions across six countries. … (more)
- Is Part Of:
- International journal of gynaecology and obstetrics. Volume 143(2018)Supplement 1
- Journal:
- International journal of gynaecology and obstetrics
- Issue:
- Volume 143(2018)Supplement 1
- Issue Display:
- Volume 143, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 143
- Issue:
- 1
- Issue Sort Value:
- 2018-0143-0001-0000
- Page Start:
- 20
- Page End:
- 27
- Publication Date:
- 2018-09-18
- Subjects:
- Absent thread -- Complications -- Expulsions -- FIGO initiative -- Outcomes -- Postpartum intrauterine device -- PPIUD -- Removal
Gynecology -- Periodicals
Obstetrics -- Periodicals
Electronic journals
618 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00207292 ↗
http://www.sciencedirect.com/science/journal/00207292 ↗
https://obgyn.onlinelibrary.wiley.com/journal/18793479 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1002/ijgo.12600 ↗
- Languages:
- English
- ISSNs:
- 0020-7292
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.273000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14323.xml