Endoscopic ultrasonography‐guided choledochoduodenostomy using a newly designed laser‐cut metal stent: Feasibility study in a porcine model. Issue 2 (19th October 2016)
- Record Type:
- Journal Article
- Title:
- Endoscopic ultrasonography‐guided choledochoduodenostomy using a newly designed laser‐cut metal stent: Feasibility study in a porcine model. Issue 2 (19th October 2016)
- Main Title:
- Endoscopic ultrasonography‐guided choledochoduodenostomy using a newly designed laser‐cut metal stent: Feasibility study in a porcine model
- Authors:
- Minaga, Kosuke
Kitano, Masayuki
Gon, Chimyon
Yamao, Kentaro
Imai, Hajime
Miyata, Takeshi
Kamata, Ken
Omoto, Shunsuke
Takenaka, Mamoru
Kudo, Masatoshi - Abstract:
- Abstract : Background and Aim: Endoscopic ultrasonography (EUS)‐guided choledochoduodenostomy (EUS‐CDS) is increasingly used in the treatment of malignant distal biliary obstruction. Standardized use of this technique requires improvements in instruments, including more convenient and safer devices. The present study was designed to evaluate the resistance force to migration (RFM) of a newly designed laser‐cut metal stent and the feasibility of EUS‐CDS using this stent. Methods: This experimental study used a porcine model of biliary dilatation involving five male pigs. The new stent is a fully covered laser‐cut stent with anti‐migration anchoring hooks. The RFM of the new stents was compared with those of three commercially available covered metal stents using a phantom model. In the animal study, after ligation of Vater's ampulla with endoscopic clips, the dilated common bile duct was punctured under EUS guidance, followed by EUS‐CDS using the new stent. One week after the procedure, the stents were removed endoscopically and the fistulas were assessed after the pigs were killed. Technical feasibility and clinical outcomes were evaluated. Results: Among the four stents, the new stent had the highest RFM. Metal stent placement was successful in all five pigs, with no procedure‐related complications occurring during and 1 week after endoscopic intervention. All stents remained in place without migration and were removed easily using a snare. At necropsy, fistulas wereAbstract : Background and Aim: Endoscopic ultrasonography (EUS)‐guided choledochoduodenostomy (EUS‐CDS) is increasingly used in the treatment of malignant distal biliary obstruction. Standardized use of this technique requires improvements in instruments, including more convenient and safer devices. The present study was designed to evaluate the resistance force to migration (RFM) of a newly designed laser‐cut metal stent and the feasibility of EUS‐CDS using this stent. Methods: This experimental study used a porcine model of biliary dilatation involving five male pigs. The new stent is a fully covered laser‐cut stent with anti‐migration anchoring hooks. The RFM of the new stents was compared with those of three commercially available covered metal stents using a phantom model. In the animal study, after ligation of Vater's ampulla with endoscopic clips, the dilated common bile duct was punctured under EUS guidance, followed by EUS‐CDS using the new stent. One week after the procedure, the stents were removed endoscopically and the fistulas were assessed after the pigs were killed. Technical feasibility and clinical outcomes were evaluated. Results: Among the four stents, the new stent had the highest RFM. Metal stent placement was successful in all five pigs, with no procedure‐related complications occurring during and 1 week after endoscopic intervention. All stents remained in place without migration and were removed easily using a snare. At necropsy, fistulas were created between the bile duct and duodenum in all pigs. Conclusion: EUS‐CDS using a newly designed metal stent was feasible and effective in this porcine model of biliary dilatation. … (more)
- Is Part Of:
- Digestive endoscopy. Volume 29:Issue 2(2017)
- Journal:
- Digestive endoscopy
- Issue:
- Volume 29:Issue 2(2017)
- Issue Display:
- Volume 29, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2017-0029-0002-0000
- Page Start:
- 211
- Page End:
- 217
- Publication Date:
- 2016-10-19
- Subjects:
- anti‐migration -- endoscopic ultrasonography (EUS) -- EUS‐guided biliary drainage -- EUS‐guided choledochoduodenostomy -- metal stent
Digestive organs -- Diseases -- Periodicals
Digestive organs -- Diseases -- Diagnosis -- Periodicals
Endoscopy -- Periodicals
Digestive System Diseases -- diagnosis -- Periodicals
Digestive System Diseases -- therapy -- Periodicals
Endoscopy -- Periodicals
616.3 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/den.12741 ↗
- Languages:
- English
- ISSNs:
- 0915-5635
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3588.346200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14319.xml